SPECIFICATIONS 

Rated Input Flow 

10 GPM 

Maximum Pressure 

3,000 PSI 

Adjustable Pressure 

Range 

50 to 3,000 PSI 

Preset Pressure 

2,100 PSI 

Filtration 

Requirement 

10 Micron minimum 

Temperature Range  -30°C to 120°C  

(-22°F to 250°F) 

Port Size 

8 ORB 

 

INTRODUCTION 

This valve protects the cylinder/motor from 

high pressure spikes by diverting hydraulic oil 

from circuit's high pressures side to the low 

pressure side. Install the Cross Over Relief 

Valve between the directional control valve 

and the cylinder/motor. 
 
 
 
 

SAFETY 

WARNING! Read and understand all instructions 

before using this device. The operator must 

follow basic precautions to reduce the risk of 

personal injury and/or damage to the equipment. 

Keep this manual for safety warnings, 

precautions, operating or inspection and 

maintenance instructions.  
1. 

Use the correct device for the job. This device 

was designed for a specific function. Do not 

modify or alter this device or use it for an 

unintended purpose. 

2.  Operate in a safe work environment. 

Keep your work area clean, well-lit and 

free of distractions. 

3.  Do not operate any device when tired 

or under the influence of drugs, alcohol 

or medications. 

4.  Always wear impact safety goggles that provide 

front and side protection for the eyes. Eye 

protection equipment should comply with CSA 

Z94.3-07 or ANSI Z87.1 standards based on the 

type of work performed. 

5.  Wear protective clothing designed for the 

work environment and device.  

6.  Consult the safety precautions for your 

hydraulic system when installing and 

operating this valve.  

 
 
 
 
 
 

UNPACKING 

WARNING! Do not operate the device if any part 

is missing. Replace the missing part before 

operating. Failure to do so could result in a 

malfunction and personal injury. 

Remove the parts and accessories from the 

packaging and inspect for damage. Make sure that 

all items in the parts list are included. 
Contents: Cross Over Relief Valve 

ASSEMBLY & 

INSTALLATION 

1. 

Connect the hoses from the directional 

control valve to Ports V1 and V2 of the 

relief valve.  

2.  Connect the hoses from the hydraulic 

cylinder/motor to Ports C1 and C2 of the 

relief valve. 

3.  Set the relief valve 

to approx. 300 PSI 

over the maximum 

pressure desired by 

turning the 

adjustment screw.  
3.1  Turning inward increases pressure, 

while turning outward decreases 

pressure. 

3.2  One full turn will increase/decrease 

pressure by approx. 580 PSI. 

 

10 GPM CROSS OVER RELIEF VALVE 