Pro-Ject Audio Systems Measure it E Manual Download Page 1

© Pro-Ject Audio Systems · Measure it E · Revision 02.09.16 

 

 

Thank you for purchasing a Pro-Ject Audio Systems stylus balance. 

!

 

Warning of a hazard for the user, the unit or possible misuse  

 

Important notice 

What is in the box 

 

stylus balance 

 

calibration weight (5 g) 

 

2 LR43 (AG12) button cell batteries plus 2 pieces as backup 

 

protection pouch for the meter 

 

user guide 

Calibration 

1   

Make sure the surface is level.

 

2

  Turn on the meter with the 

ON/OFF

 button. The display will show 

0.000

 after a few seconds.   

Give your stylus balance sufficient warm up time. Usually 30 seconds  give the internal 

components time to stabilise before calibrating. 

3

  Press and hold the 

MODE

 button until the display shows 

CAL

 and then press the 

MODE

 button    

again, the display will show 

5.000 

(flashing) after 

CAL

 (flashing). 

4

  Gently place the 5g weight on the centre of the platform. After approximately 5 seconds the 

display will read 

5.000

PASS

 and 

5.000

 

Occasionally the display will show for example 

5.002

 or 

5.004

 instead of 

5.000

. This is 

no defect. It will not affect the calibration.

 

5

  Remove the weight and press 

ON/OFF

 to turn off the meter.

 

Choosing the weighting mode 

The meter has to be turned on. The display shows 

0.000

. Pressing the

 MODE

 switches between the 

different weighting modes.  
Weighting modes: gram (1g = 10mN), ounce (oz), pennyweight (dwt) and carat (ct). 

Cartridge downforce adjustment - weighting mode gram 

1   

Make sure the surface you use the turntable on is level.

 

2

  Remove the stylus guard and the stylus balance protection cover. Gently place the meter on the 

platter. Move the headshell over the weighting platform and place the tip of the needle above the 

black dot of the weighting platform. 

3

   Turn on the stylus balance with the 

ON/OFF

  button. The display will show 

0.000

 after a few 

seconds. Give your meter sufficient warm up time. Usually 30 seconds to give the internal 

components time to stabilise. 

4

  Gently lower the tonearm until the stylus is on the black dot of the weighting platform. The display     

shows the tracking force. 

5

    Lift the tonearm and adjust the counter weight (tracking weight dial) and repeat the above 

procedure until the recommended tracking force is achieved. 

 

!

 

Never load the stylus balance with more than 

5g

, overloading can permanently damage it.

 

Reviews: