background image

© Audio Trade GmbH · Pro-Ject Debut III/Phono USB / Ortofon OM 5E · Revision 15.06.11/15.07.11

 

 

5

Switching on and off 

Pressing the power switch (20) alternately starts or stops the motor.

 

Changing replay speed

 

To play records at 45 r.p.m. first remove the platter (5). Using the accessory tool provided (3a), hook the belt 
(3) over the larger diameter part of the motor pulley (2). Refit the platter. To revert to 33,33 r.p.m. repeat the 
proceedings using the smaller step on the pulley. 

 

When the Pro-Ject Speed Box ore the Speed Box SE are used speed change between 33 and 45 r.p.m. 
is electronic. There is no need to move the belt manually.  

*** 

In addition, 78 r.p.m. is available after fitting a special pulley, which may be purchased as an 

     optional extra. 
For detailed product information please refer to the Pro-Ject web site 

www.project-audio.com

.

 

Maintenance and cleaning 

Your record player requires little or no regular maintenance. Remove dust with a slightly moistened antistatic 
cloth. Never use a dry cloth because this will create static electricity which attract more dust! Antistatic 
cleaning fluids are available at specialist stores but must be applied sparingly to avoid damage to rubber 
parts. It is recommended to fit the needle cover before cleaning or maintenance is carried out to avoid damage. 
If the player is not used over a long period of time the drive belt can be removed to prevent unequal stretching. 

!

 

Always disconnect the record player from the mains power supply as a precaution before maintenance! 

Useful tips 

The record player should be positioned on a low-resonance surface such as wood or multiple layer ply board 
to avoid structural vibrations disturbing replay.

 

Fitting and connecting the cartridge 

** All cartridges with half inch mounting holes can be fitted. Leaving the needle's protection cover on, fit the 
cartridge to the headshell using the screws supplied with the cartridge by passing one screw through each 
slot in the headshell (21). Do not tighten the nuts yet. 
Connect the tonearm wires to the cartridge pins as follows: 
white   

left channel positive (L+) 

red 

 

right channel pos. (R+) 

green   

right channel return (R -) 

blue 

 

left channel return (L -) 

The full sound quality of the record player can only be achieved if the cartridge is correctly adjusted. Particular 
tools like the PRO-JECT alignment tool are required to accomplish this job properly.  
If you are not well acquainted with the adjustment of cartridges you are advised to call upon the willing help of 
your PRO-JECT dealer to accomplish this task for you.

 

Adjusting the azimuth 

** The cartridge needle must be vertical in the record groove in order to trace 
the groove wall modulations correctly. 
A small screw at the bearing end of the arm allows incorrect azimuth to be 
corrected if your needle is not mounted exactly perpendicular to the cartridge 
body (which is often the case). 
Slacken off the screw just enough to be able to revolve the arm tube without 
applying force. Note! Do not remove the screw completely!

 

Screw

 

With the aid of a good magnifying glass adjust the needle until it is vertical in the groove (i.e. perpendicular 
to the record's surface). Ideally this should correspond to the top surface of the cartridge body being parallel 

to the record surface. When you are satisfied that the needle is vertical retighten the screw carefully.

 

 

Under no circumstances should the arm tube be adjusted with the needle still in the record groove! 
Irreparable damage may be caused to the cantilever suspension! The arm must be lifted to make 
each adjustment and lowered afterwards to check it. 

Summary of Contents for Debut III/Phono USB

Page 1: ...INSTRUCTIONS FOR USE Pro Ject Debut III Phono USB...

Page 2: ...Audio Trade GmbH Pro Ject Debut III Phono USB Ortofon OM 5E Revision 15 06 11 15 07 11 2 10 11 12 2 3 4 5 11 11 20 22 1 1 21 25 0 30 5 21 8 6 16 6a 18 9 17 15 7 14 13 9a 17 3a 23 24...

Page 3: ...notice Your turntable has been delivered with a factory fitted and adjusted cartridge please ignore the cartridge set up instructions unless changing the cartridge at a later date During assembly and...

Page 4: ...ht s thread over the second groove of the stub to set the correct anti skating force for the factory fitted cartridge Feed the thread through the loop of the wire support 17 Connection to the amplifie...

Page 5: ...ing and connecting the cartridge All cartridges with half inch mounting holes can be fitted Leaving the needle s protection cover on fit the cartridge to the headshell using the screws supplied with t...

Page 6: ...e found assistant will automatically detect the unit and announces it as a USB audio codec 3 open the System menu via Start Windows key Settings Control Panel Sound and Audio Devices 4 In the control...

Page 7: ...is powered on Please note Connection should be made to an USB socket of your computer directly Connecting to USB hubs or switches can cause problems 2 Open the Recording panel Start Control Panel Hard...

Page 8: ...C should be selected usually preselected 4 Close the control panel windows and start your recording programme Recording Programme In case you do not have a recording programme installed on your comput...

Page 9: ...o mains at the socket Drive belt is not fitted or has slipped off No signal through one or other channel or both channels No signal contact from the cartridge to the internal tonearm wiring or from th...

Page 10: ...k of H Lichtenegger This guide was produced by Audio Trade GmbH Copyright 2007 All rights reserved The information was correct at the time of going to press The manufacturer reserves the right to make...