background image

© Pro-Ject Audio Systems · Pro-Ject 1 

X

pression Carbon Classic / Ortofon 2M SILVER  · Revision 2014.01.03 

 

4

Set-up 

The deck is supplied partially disassembled and carefully packaged for safe transport. Carefully remove 
all parts from the transport packaging. 

Make  sure  the  surface  you  wish  to  use  the  turntable  on  is  level  (use  a  spirit  level)  before  placing  the 
turntable on it.  

Fit the drive belt (3) around the hub (4) and the smaller diameter part of the  motor pulley (2). Avoid 
getting  sweat  or  grease  on  the  belt  as  these  will  deteriorate  the  performance  and  reduce  the  belt's 
lifespan. Use absorbent kitchen paper to remove any oil or grease from the outer edge of the hub and the 
belt.  

Fit the platter over the spindle of the hub.  Level  the  plinth  using  a  spirit  level  and  the  adjustable  feet 
(23). 

Remove the transport lock (18) from the tonearm. Store it in the original packaging so it is available for 
any future transportation. 

 

We recommend to use the record player without a mat on the platter. 

Cartridge downforce adjustment 

The  counterweight  (6)  supplied  is  suitable  for  cartridges  weighing  between  6  -  8g  (counterweight 
no.

48

). 

Adjust the downforce prior to installing the anti-skating weight. 

Pushing  carefully,  turn  the  counterweight  (6)  onto  the  rear  end  of  the  tonearm  tube  (9),  so  that  the 
downforce scale (6a) shows towards the front of the player. Lower the armlift and position the cartridge 
in  the  space  between  arm  rest  and  platter.  Carefully  rotate  the  counterweight  (6)  until  the  armtube 
balances  out.  The  arm  should  return  to  the  balanced  position  if  it  is  moved  up  or  down.  This 
adjustment must be done carefully. Do not forget to remove the cartridge protection cap if fitted. 

Once  the  arm  is  correctly  balanced  return  it  to  the  rest.  Hold  the  counterweight  (6)  without  moving  it, 
and gently revolve the downforce scale ring (6a) until the zero is in line with the anti-skating prong (15). 
Check whether the arm still balances out. 

Rotate  the counterweight counter  clockwise (seen from the front) to  adjust the  downforce  according 
to the cartridge  manufacturer's recommendations. One  mark on  the scale represents 1  mN (= 0,1g / 
0,1 Pond) of downforce. 

 

The recommended downforce for the factory fitted cartridge is 

18mN

Adjusting the vertical tracking angle (vta)

 

** Put a record and the record weight on the platter. When the needle is lowered into the record groove 
and the tonearm is not resting on the lift arm, the tube of the tonearm should be parallel to the surface of 
the record.  

If it is not, loosen hexagon screw in the tonearm base just enough to allow vertical movement of the 
arm pillar without force and slide the arm up or down until it is parallel.  

Carefully retighten  the  hexagon  screw  without  applying  excessive force  (which would  deform  the  arm 
pillar) – finger tight is quite sufficient. 

Adjusting the azimuth 

** The cartridge needle must be vertical in the record groove in order 
to trace the groove wall modulations correctly. 

A small screw at the bearing end of the arm allows incorrect azimuth to 
be  corrected  if  your  needle  is  not  mounted  exactly  perpendicular  to 
the cartridge body (which is often the case). 

Slacken  off  the  screw  just  enough  to  be  able  to  revolve  the  arm  tube 
without  applying  force.  Please  note:  do  not  remove  the  screw 
completely!

 

 

Summary of Contents for 1 Xpression Carbon Classic

Page 1: ...INSTRUCTIONS FOR USE Pro Ject 1 Xpression Carbon Classic ...

Page 2: ... Pro Ject Audio Systems Pro Ject 1 Xpression Carbon Classic Ortofon 2M SILVER Revision 2014 01 03 2 ...

Page 3: ...p toe feet with anti scratch cups Connection cable not shown Power supply not shown Universal adapter not shown Dear music lover thank you for purchasing a PRO JECT AUDIO record player In order to achieve maximum performance and reliability with this record player you should study these instructions for use carefully Warning of a hazard for the user the unit or possible misuse Important notice The...

Page 4: ... the balanced position if it is moved up or down This adjustment must be done carefully Do not forget to remove the cartridge protection cap if fitted Once the arm is correctly balanced return it to the rest Hold the counterweight 6 without moving it and gently revolve the downforce scale ring 6a until the zero is in line with the anti skating prong 15 Check whether the arm still balances out Rota...

Page 5: ...e sure that the phono input offers correct matching and amplification for the type of cartridge used Line inputs such as CD Tuner Tape or Video are not suitable Take care to connect the left and right channels correctly The right channel is usually marked red the left channel black or white Check the manual supplied with your amplifier for relevant information The earthing wire of the tonearm lead...

Page 6: ...artridge All cartridges with half inch mounting holes can be fitted Leaving the needle s protection cover on fit the cartridge to the headshell using the screws supplied with the cartridge by passing one screw through each slot in the headshell 21 Do not tighten the nuts yet Connect the tonearm wires to the cartridge pins as follows white left channel positive L red right channel pos R green right...

Page 7: ...g Effective tonearm length 8 6 218 5mm Overhang 18 5mm Power consumption 4W 0W standby mode Outboard power supply 15V 0 0 8mA DC set at 0 5mA universal power supply Dimensions W x H x D 415 x 130 x 335mm dust cover open 415 x 400 x 400mm Weight 5 5kg Technical specifications MM Cartridge Ortofon 2M SILVER Frequency range 20 22 000Hz Channel separation 23dB 1kHz Output voltage 4mV Recommended load ...

Page 8: ...overstretched or dirty platter bearing without oil dirty or damaged Service Should you encounter a problem which you are not able to alleviate or identify despite the above information please contact your dealer for further advice Only when the problem cannot be resolved there should the unit be sent to the responsible distributor in your country Guarantee repairs will only be effected if the unit...

Page 9: ... Pro Ject Audio Systems Pro Ject 1 Xpression Carbon Classic Ortofon 2M SILVER Revision 2014 01 03 9 ...