6

result in damage to the device or injury to the operator. Contact a licensed service cen-
ter in case of failure
• Do not turn on the counter if the power cord is damaged
• If the device was exposed to cold for an extensive period of time, it is necessary to
keep it at the room temperature for no less than 4 hours
Remember! The producer is in no way responsible for damage to the device or injury to
the operator in the event of incorrect operation /care of the device.

6

Counterfeit detection  

6.1. UV detection (for PRO 57UM/S and PRO-57U models)

The UV detector is designed for various currencies and all banknote types.

The counter automatically tests the UV reflection level of the banknotes. If the level is

incorrect, the device stops counting and “Eu” error is displayed. Suspicious banknotes
will always be placed on top of the output stack. Such banknote should be verified for
authenticity. Remember that original banknotes accidentally exposed to hostile environ-
ment can also have an incorrect UV-level.
Press “UV” button to switch on the mode. The backlighting LED will light up. The UV
detector functions in any counting operation mode.

6.2. Magnetic detection (for PRO 57UM/S model)

The magnetic detector is designed for EURO and USD detection.
The device automatically tests the presence of magnetic marks on the banknote. If there
are no MG marks, the counter stops counting and “En” error is displayed. Suspicious
banknotes will always be placed on top of the output stack. Such banknote should be
verified for authenticity.
Press  “

E$

” button to switch on magnetic detector. The backlighting LED will light up.

7

Counter operation 

7.1. Preparation

• Connect the power cord to the device as shown in Fig. 1-6
• Turn power switch (Fig. 1-9) ON
• The “PRO” logo will appear on the screen while in batch mode
• The model type will be seen on the main screen. If an error message is shown on the
batch mode display as listed in Table 8, contact a service center
• Counter starts
• When self test mode is finished, the display will read “0” and the counter is ready for
operation
Optical density detection is switched on as default.

7.2. Counting procedure
ATTENTION

! To avoid errors in counting, sort banknotes and put aside the following:

banknotes with excessive wear and tear, banknotes that have been exposed to chemi-
cals including detergents, banknotes that have unofficial markings on them, etc.

Summary of Contents for PRO 55E

Page 1: ...PRO 57 SERIES 57 57U 57UM S 55R 55S 55E www pro intell com User manual Currency counters English...

Page 2: ...o easily and quickly become acquainted with the device its functions and its capabilities Please read this manual to ensure proper operation of the device 1 PRO 57 series Main functions This device is...

Page 3: ...play depicts counting results and operational information in case of changes in the following parameters Counting speed Sensitivity level of magnetic sensor Sensitivity level of UV sensor Sensitivity...

Page 4: ...play 1 and 2 After pressing the button the device quits batch mode and resets the summation and counting results 10 SP button The SP button changes the counting speed Each pressing of SP button change...

Page 5: ...5 Figure 2...

Page 6: ...he UV detector functions in any counting operation mode 6 2 Magnetic detection for PRO 57UM S model The magnetic detector is designed for EURO and USD detection The device automatically tests the pres...

Page 7: ...unt of banknotes to be calculated Press digital buttons Fig 2 7 to set the number of banknotes that need to be counted Repeat from the beginning of Table 7 2 Remove banknotes from the stacker Add bank...

Page 8: ...Press START button to enter a new figure in the data store and exit sensitivity level change mode 8 2 3 Changing the optical density sensitivity banknote transparency It should be noted that a single...

Page 9: ...of halved banknote 2 Failure of left or right sensors of the counter 1 Remove the banknotes from the stacker and take away the suspicious banknote lying on the top Repeat the counting procedure 1 Con...

Page 10: ...ch on off the power clean the sensor or contact service centre E 1 Right sensor is either blocked or failed Switch on off the power clean the sensor or contact service centre E 2 Sensor in the stacker...

Page 11: ...rged separately Warranty service does not include any training for equipment maintenance or other use of the device connection testing customizing preventive works etc which the customer can complete...