background image

 

 

10,000W HEAVY DUTY HEATER

 

 

OWNER’S MANUAL 

 

Model No.: PH-9100WS 

10000W  240V  60Hz 

7500W 208V 60Hz 

 

 

 
 
 
 
 

 
 
 
 

 

 
   

                                                                                                           

                                                                                                                   

 

                                           

IMPORTANT INSTRUCTIONS 

READ & SAVE 

PET OWNERS WARNING: 

The health of some small pets including birds are extremely sensitive to the fumes 
produced during the first-time use of many appliances. These fumes are not harmful 
to humans but we recommended that you do not use your heater around birds and 
small pets during its initial use until the manufacturing corrosion coatings burn off. 

 

Technical support: 1-866-206-0888

 

Service email:

Summary of Contents for PH-9100WS

Page 1: ...l pets including birds are extremely sensitive to the fumes produced during the first time use of many appliances These fumes are not harmful to humans but we recommended that you do not use your heat...

Page 2: ...TABLE OF CONTENTS Important Instructions 3 Specifications and Wiring Diagram 4 Parts of the heater 4 5 Installing Instructions 5 7 Operating Instructions 7 Maintenance and Cleaning 7 Troubleshooting...

Page 3: ...been dropped or damaged in any manner Disconnect power at service panel and have heater inspected by a reputable electrician before reusing 6 Do not use outdoors 7 To disconnect heater turn off power...

Page 4: ...DUTY HEATER Model PH 9100WS Voltage 1 Phase 208 240 V Watts 7500 10000 W Frequency 60 Hz Recommended Heating Capacity 1 25 watts ft 0 03m Wiring diagram PARTS OF THE HEATER SPECIFICATIONS A E B C D F...

Page 5: ...pole as main cutoff switch of power connection to the heater Wiring compartment for accommodating supply cables and pigtail leads are adequate and measured free space of 2524 67 cm3 CAUTION High temp...

Page 6: ...operly with connectors which are suitable for the conductor size in cluding grounding wirings Pull all the conductors from the conduit Strip 3 4 inch of insulation from each of the insulated conductor...

Page 7: ...aker to turn on the heater power Press the switch at the back of the heater to turn on the fan and heating function To turn off the heater press the switch turn off the fan and heating function And th...

Page 8: ...as been tripped Check your electrical box to confirm the breaker has not been blown This may occur if the receptacle is shared between other high consumption appliances The heater is producing a burni...

Reviews: