ATTACHING AND REMOVING THE ACCESS PANEL

Turn off the spa power. Remove the eight #10 x 2”
Machine Screws (37) that secure the indicated Access
Panel (25) to the spa. Carefully remove the Access
Panel until the CD wire harness (not shown) is visible
and disconnect it. Set the Access Panel aside. 

Be

careful not to damage the spa shell.

To replace the Access Panel (25), hold the Access
Panel in place, connect the CD wire harness to the
CD Player and reattach the Access Panel to the spa
with the eight #10 x 2” Machine Screws (37). 

Be

careful not to overtighten the Screws.

DRAINING THE HYDROTHERAPY SPA

The hydrotherapy spa should be drained at least four
times per year and refilled with clean water. You may
need to drain the spa more often, depending on the
user load. This must be done because after repeated
chemical treatment the water becomes chemically
saturated. Once this happens, additional chemical
treatment of the water is no longer effective. The spa
should also be drained if you will not be using it for
long periods of time. The spa must always be drained
before major repairs are made.

The hydrotherapy spa should always be covered
when it is empty. Direct sunlight can cause exten-
sive damage. The surface of the spa shell can
reach temperatures as high as 150°F in a matter
of minutes if exposed to the sun while it is empty.
These high temperatures can cause significant
damage, such as blistering of the shell surface

and warping of the spa shell. Any damage caused
by sun exposure is not covered under warranty.

To drain the hydrotherapy spa, follow the steps below:

1. Using the console, adjust the temperature to the

lowest setting.

2. Shut off the power to the spa, at the circuit break-

er or GFCI.

3. Remove the access panel from the spa (see

ATTACHING AND REMOVING THE ACCESS
PANEL on this page).

4. Pull the drain hose out and hold it above the

waterline. Remove the cap, open the valve knob,
and attach a garden hose to the drain hose. Lower
the drain hose and drain the spa.

5. When the spa is empty, remove the garden hose,

close the valve knob, and reattach the cap and
return the drain hose inside the spa. 

6. Reattach the access panel.
7. Refill the spa and treat the water with chemicals

(see pages 12 and 17).

25

37

37

Drain

Hose

Valve

Knob

Cap

Summary of Contents for MAGNUM PFSB53950

Page 1: ...t line will provide immediate assistance free of charge CUSTOMER HOT LINE 1 888 884 6555 Mon Fri 8 a m 5 p m CST Model No PFSB53950 Serial No The serial number is on a sign behind the access panel Wri...

Page 2: ...shooting 20 Part List 22 Exploded Drawing 23 Ordering Replacement Parts Back Cover Limited Warranty Back Cover The warning sign shown below must be posted on a wall or fence where it will be visible t...

Page 3: ...s can cause significant damage such as blistering of the shell surface and warping of the spa shell Any damage caused by sun exposure is not covered under the warranty 9 Do not bring any object into t...

Page 4: ...njury Pregnant women should consult with their physician before using the hydrotherapy spa Pregnant women should not use the spa if the water temperature is above 100 F the unborn child could be serio...

Page 5: ...NING The spa jets produce a stream of water with relatively high pressure Prolonged exposure of a localized area of the body may cause bruises to the skin 36 The included warning sign must be posted w...

Page 6: ...or your benefit read this manual carefully before using the hydrotherapy spa If you have questions after reading the manual please call our Customer Service Department toll free at 1 888 884 6555 Mond...

Page 7: ...he spa provided you leave access to the motor for service 9 Make sure to note any other considerations such as aesthetics or privacy concerns that may affect the safety or enjoyment of using the spa I...

Page 8: ...or conduit within five feet of the spa Three options for wiring the spa are shown at the right A wiring diagram is also found on the inside of the electronics pack for reference Option 1 Main Panel GF...

Page 9: ...ible and disconnect it Set the Access Panel aside Be careful not to damage the spa shell Insert the Pillow 38 into the lounge seat receptacle Note The Pillow can be rotated 180 and reattached in a hig...

Page 10: ...s at the level of the molded fill line Do not overfill the spa See the inset drawing Set the Filter 5 and the Basket 22 in the filter housing Next place the Filter Cover 3 in the filter housing 4 Pull...

Page 11: ...A countdown from 005 to 000 will appear in the display of the console Once the countdown has reached 000 Pr will be displayed Pr indicates that the controller is in the two pump priming mode This mod...

Page 12: ...hould resume normal operation If the spa continues to run after the test button is pressed the GFCI is damaged Do not use the spa until the GFCI has been repaired or replaced by a qualified electricia...

Page 13: ...uction covers should always be in place over the fittings Never operate the spa with out the suction covers in place F The ozone generator helps sanitize the spa with minimal chemical treatment during...

Page 14: ...e spa to within 20 F of the set temperature during the filter cycles only Slp is always displayed when the actual temperature does not equal the set temperature Slp alternates with the actual temperat...

Page 15: ...the temperature set ting of the water The temperature setting can be from 80 F to 104 F The startup temperature is set at 100 F The water heats at about 6 F per hour with the cover on Use a medical or...

Page 16: ...AINING THE SPA EXTERIOR The surround is maintenance free The surround should be cleaned with a mild soap solution do not use solvents or waxes CLEANING THE SPA SHELL The spa shell should be cleaned wi...

Page 17: ...t unit Also the sani tation agents in the water will not be effective if the pH level is not properly maintained Damage caused by improper pH levels is not covered under the warranty To maintain the p...

Page 18: ...f time The spa must always be drained before major repairs are made The hydrotherapy spa should always be covered when it is empty Direct sunlight can cause exten sive damage The surface of the spa sh...

Page 19: ...over each jet starting with the highest jet and fin ishing with the lowest jet 5 Set the air controls to the highest setting and repeat step 3 6 Drain the pumps see DRAINING THE PUMPS on this page Onc...

Page 20: ...Set the air control to low The water will heat at a rate of 6 F per hour If you are using the spa indoors and the room temperature is main tained at 70 F it will take approximately 6 to 8 hours for th...

Page 21: ...s on the floor around the hydrotherapy spa the spa shell may have a leak Contact your local pool and spa service provider for repairs 10 SYMPTOM THE SPA JET UNIT CONTINUES TO RUN AFTER IT HAS BEEN SHU...

Page 22: ...4 Washer 32 1 Face Plate 33 6 Panel 34 2 Heater Collar With Screw 35 1 Volcano Jet 36 2 Drain Plug 37 48 10 x 2 Machine Screw 38 2 Pillow 39 2 Drain Plug O ring 40 4 Corner Panel 41 2 Neck Jet 42 1 F...

Page 23: ...7 37 37 33 9 38 14 9 9 41 41 43 43 40 7 8 34 34 1 44 42 5 3 24 2 13 19 28 23 31 13 6 36 39 23 31 4 13 10 28 13 6 36 39 23 31 23 31 4 31 9 9 31 46 9 31 31 31 31 22 37 37 48 49 50 51 47 38 Exploded Draw...

Page 24: ...idents any damage to the premium cedar surround or frame attributable to improper handling or freight damage damage resulting from improper winterization damage to the spa shell resulting from imprope...

Reviews: