Pro-Form BIOVIBE User Manual Download Page 3

3

WARNING:

To reduce the risk of serious injury, read all important precautions and

instructions in this manual and all warnings on your vibration platform before using your vibration

platform. ICON assumes no responsibility for personal injury or property damage sustained by or

through the use of this product.

IMPORTANT PRECAUTIONS

1. Before beginning any exercise program,

consult your physician. This is especially

important for persons over the age of 35 or

persons with pre-existing health problems.

2. It is the responsibility of the owner to ensure

that all users of the vibration platform are

adequately informed of all precautions.

3. Your vibration platform is intended for home

use only. Do not use your vibration platform

in a commercial, rental, or institutional set-

ting.

4. Keep your vibration platform indoors, away

from moisture and dust. Place your vibration

platform on a level surface, with a mat

beneath it to protect the floor or carpet. Do

not place the vibration platform in a garage

or covered patio, or near water.

5. Inspect and properly tighten all parts regu-

larly. Replace any worn parts immediately.

6. Keep children under age 12 and pets away

from your vibration platform at all times.

7. Your vibration platform should not be used

by persons weighing more than 250 lbs.

(113 kg).

8. Never allow more than one person on the

vibration platform at a time.

9. Keep your back straight while using your

vibration platform; do not arch your back.

When standing on the vibration platform,

bend your knees slightly and balance your

weight on the balls of your feet.

10. It is recommended that you use the vibration

platform no more than 15 minutes per day

and no more than 3 times per week.

11. Be careful when stepping down from the

vibration platform; your muscles will feel dif-

ferent after you exercise on the vibration

platform.

12. The following is a list of factors and condi-

tions that may make exercising on the vibra-

tion platform inadvisable (this list is not

exhaustive; it is intended only for reference).

If one or more factors or conditions apply to

you, consult your physician before using the

vibration platform.

• Knee or hip implant

• Pacemaker

• Recently placed screws, pins, bolts, or

spirals

• Acute hernia, discopathy, or spondylitis

• Serious heart or vascular disease

• Acute thrombosis

• Tumor

• Serious migraine

• Epilepsy

• Serious diabetes

• Recent wound due to operation

• Fresh inflammation

• Pregnancy

13. If you feel pain or dizziness while exercising,

stop immediately and cool down.

14. Use your vibration platform only as

described in this manual.

15. When connecting the power cord, follow the

instructions on page 7.

16. Do not modify the power cord or use an

adapter to connect the power cord to an

improper receptacle. Keep the power cord

away from heated surfaces.

17. Never leave the vibration platform unattend-

ed while it is running.

18.

DANGER:

Always unplug the power

cord when the vibration platform is not in

use and before cleaning the vibration plat-

form. Servicing other than the procedures in

this manual should be performed by an

authorized service representative only.

Summary of Contents for BIOVIBE

Page 1: ...PLEASE CONTACT THE STORE WHERE YOU PURCHASED THIS PRODUCT Electrical Specifications 120V 60 Hz Type Y Vendor Comercializadora Mexico Americana S de R L de C V Av Nextengo No 78 Col Santa Cruz Acayuca...

Page 2: ...IST 10 EXPLODED DRAWING 11 2 WARNING DECAL PLACEMENT PROFORM is a registered trademark of ICON IP Inc This drawing shows the location s of the warning decal s If a decal is missing or illegible see th...

Page 3: ...ch your back When standing on the vibration platform bend your knees slightly and balance your weight on the balls of your feet 10 It is recommended that you use the vibration platform no more than 15...

Page 4: ...rm If you have ques tions after reading this manual please see the front cover of this manual To help us assist you note the product model number and serial number before con tacting us The model numb...

Page 5: ...and the Front Post 26 to the position shown Attach the Handlebar Frame to the Bottom Frame 18 with the two M8 Knobs 27 Then insert the Control 43 into the Control Holder 32 2 Attach the Left Handleba...

Page 6: ...l parts are properly tightened each time you use the vibration platform Replace any worn parts immediately Outer surfaces of the vibration platform can be cleaned with a damp cloth and a mild non abra...

Page 7: ...onents may become damaged Plug in the adapter as described above Next press the On Off button on the control The power indicator will light and the vibration platform will begin to vibrate Note The vi...

Page 8: ...press the On Off button The power indicator will darken Unplug the adapter when the vibration platform is not in use CONTROL TROUBLESHOOTING If the control does not function properly make sure that th...

Page 9: ...9 NOTES...

Page 10: ...M8 Knob 28 1 Handlebar Frame 29 2 Handlebar Frame Cover 30 2 M8 x 25mm Screw 31 4 M8 Arc Washer 32 1 Control Holder 33 2 M3 5 x 32mm Self tapping Screw 34 1 Motor Pad 35 2 Handlebar Cover 36 1 Left Ha...

Page 11: ...6 6 3 3 9 10 10 10 11 20 15 11 20 39 4 4 13 13 14 21 23 22 40 16 16 16 18 10 19 10 10 10 10 7 19 10 6 6 6 6 19 3 3 3 3 19 8 7 19 47 4 4 41 3 24 45 26 17 30 32 33 12 12 10 29 25 25 27 27 28 29 10 6 31...

Page 12: ...Part No 273875 R0908A Printed in China 2008 ICON IP Inc...

Reviews: