background image

14

HOW TO PLUG IN THE POWER CORD

Your vibration platform, like any other type of sophisti-

cated electronic equipment, can be seriously damaged

by sudden voltage changes in your homeʼs power.

Voltage surges, spikes, and noise interference can

result from weather conditions or from other appliances

being turned on or off.

To decrease the possibility of

your vibration platform being damaged, always

use a surge suppressor with your vibration plat-

form (see drawing 1 at the right). To purchase a

surge suppressor, see your local Sears store or

call the telephone number on the back cover of

this manual and order part number 146148, or see

your local electronics store.

Use only a single-outlet surge suppressor that is

UL 1449 listed as a transient voltage surge sup-

pressor (TVSS). The surge suppressor must have

a UL suppressed voltage rating of 400 volts or less

and a minimum surge dissipation of 450 joules.

The surge suppressor must be electrically rated

for 120 volts AC and 15 amps. There must be a

monitoring light on the surge suppressor to indi-

cate whether it is functioning properly.

This product must be grounded.

If it should mal-

function or break down, grounding provides a path of

least resistance for electric current to reduce the risk

of electric shock. This product is equipped with a cord

having an equipment-grounding conductor and a

grounding plug.

Plug the power cord into a surge

suppressor, and plug the surge suppressor into an

appropriate outlet that is properly installed and

grounded in accordance with all local codes and

ordinances. IMPORTANT: The vibration platform is

not compatible with GFCI-equipped outlets.

This product is for use on a nominal 120-volt circuit,

and has a grounding plug that looks like the plug illus-

trated in drawing 1 below. A temporary adapter that

looks like the adapter illustrated in drawing 2 may be

used to connect the surge suppressor to a 2-pole

receptacle as shown in drawing 2 if a properly

grounded outlet is not available.

The temporary adapter should be used only until a

properly grounded outlet (drawing 1) can be installed

by a qualified electrician.

The green-colored rigid ear, lug, or the like extending

from the adapter must be connected to a permanent

ground such as a properly grounded outlet box cover.

Whenever the adapter is used it must be held in place

by a metal screw.

Some 2-pole receptacle outlet

box covers are not grounded. Contact a qualified

electrician to determine if the outlet box cover is

grounded before using an adapter.

DANGER:

Improper connection

of the equipment-grounding conductor can

result in an increased risk of electric shock.

Check with a qualified electrician or service-

man if you are in doubt as to whether the

product is properly grounded. Do not modify

the plug provided with the product—if it will

not fit the outlet, have a proper outlet

installed by a qualified electrician.

1

2

Grounded Outlet Box

Grounded Outlet Box

Grounding Plug

Surge Suppressor

Surge Suppressor

Grounding Pin

Adapter

Lug

Metal Screw

Grounded Outlet

Grounding Pin

Summary of Contents for 831.14787.0

Page 1: ...is equipment Keep this manu al for future reference USER S MANUAL Assembly Operation Troubleshooting Part List and Drawing Model No 831 14787 0 Serial No Write the serial number in the space above for...

Page 2: ...7 PART LIST 18 EXPLODED DRAWING 19 ORDERING REPLACEMENT PARTS Back Cover 90 DAY FULL WARRANTY Back Cover 2 WARNING DECAL PLACEMENT The warning decals shown here have been applied in the locations show...

Page 3: ...not be used by persons weighing more than 300 lbs 136 kg 8 Never allow more than one person on the vibration platform at a time 9 Keep your back straight while using the vibration platform do not arc...

Page 4: ...ssor see your local Sears store or call the tele phone number on the back cover of this manual and order part number 146148 or see your local electronics store 19 Keep the power cord away from heated...

Page 5: ...f you have ques tions after reading this manual please see the back cover of this manual To help us assist you note the product model number and serial number before con tacting us The model number an...

Page 6: ...M10 x 50mm Patch Screw 51 M4 x 16mm Patch Screw 26 M10 x 68mm Bolt 55 6 See the drawings below to identify small parts used in assembly The number in parentheses by each drawing is the key number of...

Page 7: ...not dispose of the packing materials until assembly is completed For help identifying small parts see the PART IDENTIFICATION CHART on page 6 Tighten all parts as you assemble them unless instructed...

Page 8: ...Orient the Wheel Bracket 35 so that the arrow sticker is pointing upward Attach the Wheel Bracket 35 to the Lower Upright 1 with two M10 x 20mm Patch Screws 28 3 1 5 1 28 35 20 38 4 Attach the Wheel...

Page 9: ...e 41 Next attach the Upper Upright 36 to the Weight Rest Frame 41 with two M10 x 50mm Patch Screws 51 and two M10 Split Washers 38 6 36 38 51 Hole Wire Tie 41 9 7 43 Wire Tie 36 1 43 7 Have a second p...

Page 10: ...ht M5 x 38mm Screws 40 8 28 1 28 38 38 36 10 9 Tip Orient the Handlebar 39 so that the sticker with an R is in the location shown Attach the Handlebar 39 to the Upper Upright 36 with two M10 x 62mm Pa...

Page 11: ...e to the Ground Wire 52 Next connect the console wire to the Wire Harness 43 Then insert the wires into the Upper Upright 12 3 52 Console Ground Wire 36 13 Tip Be careful not to pinch the wires during...

Page 12: ...ns on a Dumbbell 44 and slide the selector pins to the adjustment holes marked 2 5 Place the Dumbbell on the weight plates Then lift the two selector pins and slide them to the adjustment holes marked...

Page 13: ...ur six eight or ten weight plates each dumbbell han dle can also be used without weight plates To select the desired number of weight plates first set a dumbbell on the weight rest as shown Next lift...

Page 14: ...e surge suppressor into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances IMPORTANT The vibration platform is not compatible with GFCI equ...

Page 15: ...FIT cards are also available at select stores HOW TO TURN ON THE POWER IMPORTANT If the vibration platform has been exposed to cold temperatures allow it to warm to room temperature before turning on...

Page 16: ...vibration sessions as desired IMPORTANT It is recom mended that you use the vibration platform for no more than 15 minutes per day and no more than 3 times per week 7 When you are finished switch the...

Page 17: ...outlet see page 14 Use only a single outlet surge sup pressor that meets all of the specifications described on page 14 IMPORTANT The vibration platform is not compatible with GFCI equipped outlets b...

Page 18: ...ocknut 33 1 M10 x 114mm Bolt 34 5 M10 x 35mm Screw 35 1 Wheel Bracket 36 1 Upper Upright 37 2 M10 x 62mm Patch Screw 38 10 M10 Split Washer 39 1 Handlebar 40 8 M5 x 38mm Screw 41 1 Weight Rest Frame 4...

Page 19: ...4 16 13 9 10 11 41 42 36 3 39 48 48 48 34 15 14 16 13 34 20 15 14 16 13 34 16 13 34 5 15 14 48 7 8 22 23 21 25 25 17 43 24 24 24 24 37 27 26 45 27 40 51 28 40 40 40 32 35 33 28 29 13 34 18 19 31 47 46...

Page 20: ...otection agreement U S A or maintenance agreement Canada on a product serviced by Sears 1 800 827 6655 U S A 1 800 361 6665 Canada Para pedir servicio de reparaci n a domicilio y para ordenar piezas 1...

Reviews: