Chapter 2 - Specifications
2-23
PL-5910 Series User Manual
251.5
+1
0
291.5
+1
0
less than
4-R3
• Be sure the thickness of the panel is from 1.6 to 10 mm.
• All panel surfaces used should be strengthened. Especially, if
high levels of vibration are expected and the PL unit’s instal-
lation surface (i.e. an operation panel’s door, etc.) can move
(i.e.open or close), due consideration should be given to the
PL unit ’s weight.
• To ensure that the PL unit’s moisture resistance is main-
tained, be sure to install the PL into a panel that is flat and
free of scratches or dents.
• Be sure all installation tolerances are maintained to prevent
the unit from falling out of its installation panel.
(Unit: mm [in.])
2.5.10 Panel Cut Dimensions
[9.90 ]
+0.04
0
[11.48 ]
+0.04
0
2.5.9
Installation Fasteners
16
[0.63]
Unit:mm[in.]
11
[0.43]
16.6
[0.65]
31[1.22]
M6
Φ
10