12
COM2
D-Sub 9 pin (socket)
RS-422/485
D-Sub 9 pin (plug)
->See 2.4.1 and Chapter4
Ethernet I/F
-
NEW!
10BASE-T/100BASE-TX
CF Card I/F
✔
->See 2.4.2
USB
I/F
Type A
->See 2.3
Type mini B
Expansion Unit I/F
->See 2.5.3
Page 1: ...1 Easy Smooth GP 3300 Series GP4000 Series Replacement Guidebook Fifth Edition Jul 2012 Copyright 2012 7 Digital Electronics Corporation All Rights Reserved...
Page 2: ...00L AGP3300 L1 D24 GP 3301S 1 AGP3301 S1 D24 GP 3301L 1 AGP3301 L1 D24 GP 3302B 1 AGP3302 B1 D24 1 It is also possible to replace GP 3301S L with GP 4301TM modular type For details please refer to GP...
Page 3: ...ERATOR INJURY OR UNINTENDED EQUIPMENT DAMAGE Before operating any of these products be sure to read all related manuals thoroughly Failure to follow these instructions can result in death serious inju...
Page 4: ...5 3 GP 4300 series 5 7 4 GP 4400 series 7 5 7 0 W 5 GP 4500 series 10 4 6 GP 4600 series 12 1 B 01 RS 232C 422 485 03 RS 485 isolation C T TFT color LCD W TFT color LCD Wide Type D A Analog Resistive...
Page 5: ...ECIFICATIONS OF GP 3301S L AND GP 4301TW 11 1 4 SPECIFICATIONS OF GP 3302B AND GP 4301TW 13 CHAPTER 2 COMPATIBILITY OF HARDWARE 14 2 1 LOCATIONS OF CONNECTOR 14 2 2 DISPLAY COLORS ONLY WHEN REPLACING...
Page 6: ...SCREEN DATA FROM GP 3300 SERIES 26 3 4 CHANGE THE DISPLAY UNIT TYPE 33 3 5 TRANSFER SCREEN DATA TO GP 4301T TW 34 3 6 DIFFERENCES OF SOFTWARE 38 CHAPTER 4 COMMUNICATION WITH DEVICE PLC 39 4 1 DRIVERS...
Page 7: ...els Panel Cutout Dimensions mm 156 W 123 5 H External Dimensions mm 167 5 W x135 H x59 5 D 169 5 W x137 H x59 5 D Touch Panel Type Resistive film Analog Memory Application 6MB UP 16MB SRAM 320KB Backu...
Page 8: ...b 9 pin socket RS 422 485 D Sub 9 pin plug RS 422 485 See 2 4 1 and Chapter4 Ethernet I F 10BASE T 100BASE TX CF Card I F See 2 4 2 SD Card I F NEW USB I F Type A See 2 3 Type mini B Expansion Unit I...
Page 9: ...3300L Monochrome 16 levels Display Resolution QVGA 320x240 pixels Panel Cutout Dimensions mm 156 W 123 5 H External Dimensions mm 167 5 W x135 H x59 5 D 169 5 W x137 H x59 5 D Touch Panel Type Resist...
Page 10: ...OM2 D Sub 9 pin socket RS 422 485 D Sub 9 pin plug RS 422 485 See 2 4 1 and Chapter4 Ethernet I F 10BASE T 100BASE TX CF Card I F See 2 4 2 USB I F Type A See 2 3 Type mini B Expansion Unit I F See 2...
Page 11: ...3301L Monochrome 16 levels Display Resolution QVGA 320x240 pixels Panel Cutout Dimensions mm 156 W x123 5 H External Dimensions mm 167 5 W x135 H x59 5 D 169 5 W x137 H x59 5 D Touch Panel Type Resis...
Page 12: ...2 D Sub 9 pin socket RS 422 485 D Sub 9 pin plug RS 422 485 See 2 4 1 and Chapter4 Ethernet I F NEW 10BASE T 100BASE TX CF Card I F See 2 4 2 USB I F Type A See 2 3 Type mini B Expansion Unit I F See...
Page 13: ...isplay Resolution QVGA 320x240 pixels Panel Cutout Dimensions mm 156 W x123 5 H External Dimensions mm 167 5 W x135 H x59 5 D 169 5 W x137 H x59 5 D Touch Panel Type Resistive film Analog Memory Appli...
Page 14: ...Type A See 2 3 Type mini B Expansion Unit See 2 5 3 Chapter 2 Compatibility of Hardware 2 1 Locations of connector Connector locations on GP 3300 series and GP 4301T TW are as follows Connector locat...
Page 15: ...3300T GP 4301T 1 Power Connector 2 Serial Interface COM1 3 Serial Interface COM2 4 Ethernet Interface 5 USB Interface Type A 6 USB Interface Type mini B 7 SD Card Interface 8 CF Card Interface 9 Expa...
Page 16: ...16 Connector locations on GP 3300S L GP 3301S L GP 3302B and GP 4301TW GP 3300S L GP 3301S L...
Page 17: ...17 GP 3302B GP 4301TW Interface names...
Page 18: ...chrome to color When the setting of the display unit type is changed from a monochrome model to a color one on GP Pro EX the data may be displayed in colors depending on the GP Pro EX version or setti...
Page 19: ...olors of the drawing or the parts on the screens after changing the Color setting 2 3 Transfer cable To transfer screen data to GP 4301T TW use a USB transfer cable or Ethernet The USB cables that can...
Page 20: ...422 485 connection after replacement Using a USB RS 422 485 Conversion Adapter PFXZCBCBCVUSR41 allows you to use GP4000 series USB interface as RS 422 485 serial interface for connection For more info...
Page 21: ...pacity SD FAT16 2GB SDHC FAT32 32GB When the setting of the output destination folder is set to CF Card on GP Pro EX if you change the display unit type the setting will automatically change to the on...
Page 22: ...or GP 4301T TW instead In this case select VCC from System Settings Device PLC in the Project menu on GP Pro EX 2 6 Backup Battery only when replacing with GP 4301T Unlike GP 3300 series GP 4301T does...
Page 23: ...GP 3300 series and GP 4301T TW are as follows GP 3300 series GP 4301T TW Color Silver Light Gray Material Aluminum alloy Resin with glass 2 9 Backup Memory SRAM only when replacing with GP 4301TW Whe...
Page 24: ...mation window appears 4 Click SRAM Information to see SRAM size Chapter 3 Replacement Procedure 3 1 Work Flow Receive screen data from GP 3300 series 1 Change the received data on GP Pro EX Remove GP...
Page 25: ...hernet for GP 3300T S L only Requirements for PC in which GP Pro EX Ver 3 00 or later is installed Check and modify the data on GP Pro EX Transfer the screen data to GP 4301T TW Connect GP 4301T TW an...
Page 26: ...unit not in any other device 2 Please use the same version or later as or than that of the software used during creating screens on GP 3300 series If you don t know the version we recommend you to us...
Page 27: ...C and GP 3300 series with an USB transfer cable If the driver of the cable has not been installed on your PC yet a dialog box will appear Please follow the instructions NOTE The Hardware Installation...
Page 28: ...ata Transfer Driver on OtasukePro for download http www pro face com otasuke download freesoft gpproex_transfer ht m An error occurs when GP Pro EX or Transfer Tool is installed An error occurs when d...
Page 29: ...ettings Information is set to USB If not click the Transfer Setting button to open the Transfer Setting dialog box Select USB in the Communication Port Settings field and click OK 4 Start GP Pro EX Tr...
Page 30: ...30 5 Click Receive Project and the following dialog box will appear Specify a place to save the received data in and a project file name and then click Save to start transfer...
Page 31: ...or not to overwrite the file is displayed 6 The following dialog box appears during transfer and you can check the communication status The display unit enters the Transferring mode and communication...
Page 32: ...pleted GP 4301T TW that is a replacement model is not equipped with a CF card slot If the display unit type is changed to GP 4301T TW the CF card setting will be replaced with the SD card setting auto...
Page 33: ...3300 series on GP Pro EX and change the display unit type to GP 4301T TW 1 Open the received project file prx on GP Pro EX 2 Click System Settings Display Change Display in Project menu and change th...
Page 34: ...nsfer data to GP 4301T TW via An USB transfer cable model CA3 USBCB 01 An USB data transfer cable model ZC9USCBMB1 A commercial USB cable USB Type A mini B A SD card for GP 4301T only USB storage devi...
Page 35: ...driver depending on the security level of Windows XP Click Continue Anyway to start installing the driver When installation is completed click Finish If the following symptoms appear on Microsoft Wind...
Page 36: ...on the display unit After transferring a project file once this screen will not appear again 3 On the GP Pro EX s State Toolbar click the Transfer Project icon to open the Transfer Tool To transfer a...
Page 37: ...ttings field and click OK 5 Click Send Project to start transfer When the following dialog box appears click Yes This dialog box doesn t appear when the same project file is sent again 6 The following...
Page 38: ...project file will be displayed 8 Close the Transfer Tool 9 Click the X mark on top right of the screen or Project Exit to close GP Pro EX 3 6 Differences of software Some functions supported by GP 330...
Page 39: ...river supports see Connectable Devices http www pro face com product soft gpproex driver driver html 4 2 Shapes of COM ports GP 3300T S L GP 3301S L GP 3302B GP 4301T TW COM1 D Sub 9 pin plug RS 232C...
Page 40: ...ls of COM1 For GP 3300T S L and GP 3301S L RS 232C plug 1 RI and VICC of Pin 9 are switched on the software VCC Output is not protected from overcurrent Please follow the current rating to avoid false...
Page 41: ...41 For GP 3302B RS 232C plug 1 RI and VICC of Pin 9 are switched on the software VCC Output is not protected from overcurrent Please follow the current rating to avoid false operation or breakdown...
Page 42: ...42 For GP 4301T TW RS 232C plug 1 RI and VICC of Pin 9 are switched on the software VCC Output is not protected from overcurrent Please follow the current rating to avoid false operation or breakdown...
Page 43: ...Signals of COM2 For GP 3300T S L and GP 3301S L RS 422 485 socket 1 VCC Output is not protected from overcurrent Please follow the current rating to avoid false operation or breakdown For GP 3302B RS...
Page 44: ...85 plug 4 4 Multilink Connection For the communication drivers that support serial multi link see Which drivers support serial multilink communication http www pro face com otasuke files manual gpproe...
Page 45: ...ice is connected via the COM1 port if GP 3300T S L or GP 3301S L is replaced with GP 4301T TW it will be connected via the COM2 port of GP 4301T TW The cable diagram can be still used Before GP 4301T...
Page 46: ...for GP 4301T TW with a COM Port Conversion Adapter CA3 ADPCOM 01 added in the following cases In all other cases the operation is not guaranteed and it s recommended to prepare a new connection cable...
Page 47: ...ing 1 After conversion of the project file data at GP Pro EX Error Check if the message The project contains features that require a SD card However the selected display does not support SD cards so t...
Page 48: ...ormation Destination Folder ii Uncheck Enable SD Card and check Enable USB Storage iii Click the Browse button and specify a destination folder iv Click OK to confirm the setting v Click Project Save...
Page 49: ...X Reference Manual 2 Check and change the destination folder setting following the steps below i Click Project Information Destination Folder ii The current setting is displayed iii After changing it...