CANopen communication cable and other recommended items

Recommended Cable Connector:
CiA-recommended CANopen (CiA DR-303-
1) -compatible DSUB 9-pin connector 
(DIN41652) .

CANopen Recommended Transfer Cable:
CiA-recommended CANopen (CiA DR-303-
1) -compatible twisted pair cables with 
shield.

• Please use your own cables or cable connectors with your guarantee.

Model No.

Manufacturer

Description

Recommended 
Cable Connector

XM2D-0901

<OMRON Co.>

DSUB 9-pin socket

TSXCANKCDF180T

<Schneider Electric>

Straight connector with 
terminal selector switch 
attached

TSXCANKCDF90T
TSXCANKCDF90TP

<Schneider Electric>

Right-angled connector with 
terminal selector switch 
attached.  
Only for use for GP-3300 
Series.

VS-09-BU-DSUB/CAN <PHOENIX CONTACT>

Connector with terminal block 
attached with terminal selector 
switch attached

SUBCON-PLUS-CAN/AX <PHOENIX CONTACT>

Straight connector with 
terminal selector switch 
attached

SUBCON-PLUS-CAN/PG
SUBCON-PLUS-CAN

<PHOENIX CONTACT>

Right-angled connector with 
terminal selector switch 
attached

CANopen 
Recommended 
Transfer Cable

TSX CAN CA50/TSX 
CAN CA100

<Schneider Electric>

Cable for CANopen
(IEC60332-1) 50 m/100 m

TSX CAN CB50/TSX 
CAN CB100

<Schneider Electric>

UL-authenticated cable for 
CANopen
(IEC60332-2) 50 m/100 m

Summary of Contents for AGP3600-U1-D24-CA1M

Page 1: ...tenance Troubleshooting Guide The manuals can be selected from the help menu of GP Pro EX or downloaded from Pro face Home Page URL http www pro face com Caution Be sure to read the Warning Caution In...

Page 2: ...400 Series and the GP 3500 GP 3600 Series E C Color Indicator Operation Mode Drawing Logic execution mode when logic is enabled Green ON OFFLINE In operation RUN Flashing In operation STOP Red ON When...

Page 3: ...ll FG Frame Ground Common with SG Communication Type 1 N Connection Method Multi Drop Connection Transfer Method CSMA NBA Half duplex serial transmission Transfer distance speed Transmission length No...

Page 4: ...e signal s reflections from the end of the cable a line termination shall be placed close to the 2 ends of the bus Connect both ends of the twisted pair cable CAN_H and CAN_L to each LT Use line termi...

Page 5: ...l selector switch attached TSXCANKCDF90T TSXCANKCDF90TP Schneider Electric Right angled connector with terminal selector switch attached Only for use for GP 3300 Series VS 09 BU DSUB CAN PHOENIX CONTA...

Page 6: ...1 UL File No E182139 The following units are UL c UL recognized components UL File No E171486 UL File No E231702 The following units are UL c UL listed products UL File No E220851 UL File No E210412 F...

Page 7: ...tional Electrical Code NFPA 70 within the United States and in accordance with Section 18 152 of the Canadian Electrical Code for units installed within Canada 2 Suitable for use in Class I Division 2...

Page 8: ...1M 1 The sales area is limited For the detailed information please be downloaded and refer the Declaration of Conformity from Pro face Home Page Digital Electronics Corporation Schneider Electric Osak...

Reviews: