background image

1

LOCAL DEHUMIDIFIER

Model: PELL0309 and PELL0310

Summary of Contents for PELL0309

Page 1: ...1 LOCAL DEHUMIDIFIER Model PELL0309 and PELL0310 ...

Page 2: ...afety means shall only be carried by competent persons The appliance is only suitable for indoor use and is not suitable for other applications Follow local grid interconnection rules while installing the appliance and ensure that it is properly grounded If you have any question on electrical installation follow the instructions of the manufacturer and if necessary ask a professional electrician t...

Page 3: ...hey have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and maintenance shall not be made by children without supervision If the supply cord is damaged it must be replaced by the manufacturer its service The appliance shall be installed in accordance with local wiring regula...

Page 4: ... away from any other wall curtains or heat sources to ensure adequate air circulation Ensure that the mains socket outlet remains accessible when the unit is in use Ensure that there is free access to the air inlet and air outlet vents POSITIONING INSTALLATION 1 Water TankHandle 2 Front Panel 3 Handle 4 Air Outlet 5 Control Panel 6 Filter 7 Frame 8 Power Cord 9 Rear Panel 10 Caster Activated carbo...

Page 5: ...s of whether the unit is operating or not 2 Water full indication light illuminates red when the drainage tank is full If light is on empty the water out of the drainage tank and make sure that the tank is repositioned properly 3 Swing Indication illuminates when Swing is selected and the air outlet louvre will oscillate 4 Timer indication light will illuminate green when you program the timer fun...

Page 6: ...ve humidity in the room is lower then the selected humidity the operation of the unit will stop automatically Fan Speed Setting Press to set the desired fan speed It can be adjusted between high speed and low speed Setting IONIC UV level Press to set the Ion UV function The green blue LED light will turn on when the ionic UV function is operating Press the button again to cancel the ionic UV funct...

Page 7: ...ak from the water tank CONTINUOUS WATER DRAINAGE The dehumidifier features a continuous drainage port Using a plastic pipe with an inner diameter of 10mm inserted into the drain hole on intermediate plate and arrange the drain pipe neatly The water in the drainage tank can be continuously drained from the continuous port on the unit into a suitable drain Drainage port ...

Page 8: ...before using Do not use any chemicals abrasives or solvents which may damage the surface of the dehumidifier Filters Clean the filters every two weeks If the filters become blocked by dust the efficiency of the dehumidifier will be reduced Remove the air filters on the front of the unit Run a vacuum cleaner lightly over the surface of the filters to remove dust If the filters are exceptionally dir...

Page 9: ...y control of flammable material Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe Presence of...

Page 10: ... containing components unless the components are constructed of materials which are inherently resistant to corrosion or are suitably protected against corrosion Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connect...

Page 11: ...so take into account the effects of aging or continual vibration from sources such as compressors or fans Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks A halide torch or any other detector using a naked flame shall not be used Leak detection methods The following leak detection methods a...

Page 12: ...uum pump is not close to any ignition sources and there is ventilation available Charging procedures In addition to conventional charging procedures the following requirements shall be followed 1 Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them 2 Cyli...

Page 13: ...stem either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holding the total system charge is available All cylinders to be used are designated for the recovered refrigerant a...

Page 14: ...BLESHOOTING Trouble Cause Solution Appliance does not work Power is off Water tank is full The ambient temperature is too low or too high Switch the power on Drain internal water tank Recommend to use the machine in at the temperature range of 7 35 o C 44 95 o F The dehumidifying function doesn t work Filters are too dirty Is the intake duct or discharge duct obstructed Clean the air filter Remove...

Page 15: ...power 480W 750W Power standby mode 0W Dehumidifying capacity 30L 24hr 40L 24hr Air flow 250m h Sound power level 47dB A Refrigerant charge R290 100g R290 130g Fan speeds 2 Recommended room floor area 25 30m 30 40m Dimensions 360x360x610mm Weight 16kg Net 17kg Gross 17kg Net 18kg Gross ...

Page 16: ... be treated as Waste Electrical Electronic Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling of the materials used Contact your local authority for details of recycling schemes in your area Man Rev 1 0 Made in China PR2 9PP PO Box 13362 Dublin 2 ...

Reviews: