background image

1

LOCAL DEHUMIDIFIER

Model: PELL0307 and PELL0308

Summary of Contents for PELL0307

Page 1: ...1 LOCAL DEHUMIDIFIER Model PELL0307 and PELL0308 ...

Page 2: ...afety means shall only be carried by competent persons The appliance is only suitable for indoor use and is not suitable for other applications Follow local grid interconnection rules while installing the appliance and ensure that it is properly grounded If you have any question on electrical installation follow the instructions of the manufacturer and if necessary ask a professional electrician t...

Page 3: ...hey have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and maintenance shall not be made by children without supervision If the supply cord is damaged it must be replaced by the manufacturer its service The appliance shall be installed in accordance with local wiring regula...

Page 4: ...unit at least 20cm away from any other wall curtains or heat sources to ensure adequate air circulation Ensure that the mains socket outlet remains accessible when the unit is in use Ensure that there is free access to the air inlet and air outlet vents POSITIONING INSTALLATION 1 Control Panel 2 Handle 3 Air Deflector 4 Caster 5 Filter Box 6 Water Tank 7 Power Cord Activated carbon filter cloth Op...

Page 5: ...ronment humidity is higher than 95 it will show 95 OPERATION The buzzer will sound several times when the unit is powered on and the LED display will show the room humidity for 3 seconds Press the power button to start the unit and press again to shut down Humidity Setting Press the key to enter humidity setting mode then press or to adjust the humidity from 40 to 80 in 5 increments indicated on t...

Page 6: ...op time from 1 to 24 hours If the unit is turned on or off manually or the water tank full condition occurs during use the timer function will be over ridden WATER DRAINAGE The dehumidifier has an internal water tank to collect water that accumulates during the cooling process This tank will need to be emptied periodically When the internal water tank is full the unit will go into standby mode and...

Page 7: ...tivities Cleaning Unplug from the mains supply before cleaning Do not splash water into the dehumidifier Clean the outside of the dehumidifier with a damp not wet cloth and dry thoroughly before using Do not use any chemicals abrasives or solvents which may damage the surface of the dehumidifier Filters Clean the filters every two weeks If the filters become blocked by dust the efficiency of the d...

Page 8: ...y control of flammable material Checking for presence of refrigerant The area shall be checked with an appropriate refrigerant detector prior to and during work to ensure the technician is aware of potentially flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with flammable refrigerants i e non sparking adequately sealed or intrinsically safe Presence of...

Page 9: ...containing components unless the components are constructed of materials which are inherently resistant to corrosion or are suitably protected against corrosion Checks to electrical devices Repair and maintenance to electrical components shall include initial safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connecte...

Page 10: ...so take into account the effects of aging or continual vibration from sources such as compressors or fans Detection of flammable refrigerants Under no circumstances shall potential sources of ignition be used in the searching for or detection of refrigerant leaks A halide torch or any other detector using a naked flame shall not be used Leak detection methods The following leak detection methods a...

Page 11: ...uum pump is not close to any ignition sources and there is ventilation available Charging procedures In addition to conventional charging procedures the following requirements shall be followed 1 Ensure that contamination of different refrigerants does not occur when using charging equipment Hoses or lines shall be as short as possible to minimise the amount of refrigerant contained in them 2 Cyli...

Page 12: ...stem either for servicing or decommissioning it is recommended good practice that all refrigerants are removed safely When transferring refrigerant into cylinders ensure that only appropriate refrigerant recovery cylinders are employed Ensure that the correct number of cylinders for holding the total system charge is available All cylinders to be used are designated for the recovered refrigerant a...

Page 13: ...e certain that flammable refrigerant does not remain within the lubricant The evacuation process shall be carried out prior to returning the compressor to the suppliers Only electric heating to the compressor body shall be employed to accelerate this process When oil is drained from a system it shall be carried out safely ...

Page 14: ...e temperature range of 7 35 o C 44 95 o F The dehumidifying function doesn t work Filters are too dirty Is the intake duct or discharge duct obstructed Clean the air filter Remove the obstruction from the discharge duct or intake duct Poor air discharge Air filter is dirty Air intake is obstructed Clean the air filter Check for obstructions Noisy operation Unit is not level Check the unit is stood...

Page 15: ...put power 260W 325W Power standby mode 0W Dehumidifying capacity 16L 24hr 20L 24hr Air flow 120m h Sound power level 47dB A Refrigerant charge R290 75g R290 90g Fan speeds 2 Recommended room floor area 16m 20m Dimensions 342x251x561mm Weight 13kg Net 16kg Gross 15kg Net 17kg Gross ...

Page 16: ... be treated as Waste Electrical Electronic Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling of the materials used Contact your local authority for details of recycling schemes in your area Man Rev 1 0 Made in China PR2 9PP PO Box 13362 Dublin 2 ...

Reviews: