TECHNICAL SPECIFICATION

INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF 

ELECTRICAL & ELECTRONIC EQUIPMENT.

When this product has reached the end of its life it must be treated as Waste Electrical & Electronic 

Equipment (WEEE). Any WEEE marked products must not be mixed with general household waste, 

but kept separate for the treatment, recovery and recycling of the materials used. Contact your local 

authority for details of recycling schemes in your area.

Made in China. PR2 9PP

Man Rev 2.0

Main voltage

220-240V ~ 50Hz

Rated input power

1350W

Power standby mode

1.0W

Cooling capacity

3.52kW (12,000BTU/h)

Dehumidifying capacity

28L/24hr

Air flow

380m³/h

Sound power level

65dB (A)

Refrigerant/charge

R290/195g

Global warming potential

0.585kgCO

2

 eq.

Energy efficiency ratio (EER)

2.6

Energy efficiency class

A

Fan speeds

2

Thermostat

16 - 31°C

Recommended room floor area

16-22m²

Dimensions

325x830x370mm

Weight

27kg

Summary of Contents for PEL01201

Page 1: ...1 LOCAL AIR CONDITIONER Model PEL01201...

Page 2: ...fety means shall only be carried by competent persons The appliance is only suitable for indoor use and is not suitable for other applications Follow local grid interconnection rules while installing...

Page 3: ...ysical sensory or mental capabilities if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with...

Page 4: ...6 Filter frame upper 7 Exhaust connector 8 Filter frame lower 9 Rubber plug 10 Plug cap 11 Power cord Accessories 12 Exhaust hose 13 Adjustable window guide 14 Exhaust hose adapter 15 Remote control 1...

Page 5: ...that there is free access to the air inlet and air outlet vents POSITIONING INSTALLATION Ventilation Installation Note The window kit is only designed for use with casement windows Screw the exhaust...

Page 6: ...ing with low fan speed MODE press this key to select cooling dehumidifying and fan mode FAN press this key to select the fan speed high or low DOWN in cooling mode press this key to reduce the tempera...

Page 7: ...ours to when the unit turns on The timer mode indicator turns on The length of time is adjustable from 1 to 24 hours In power on mode press TIMER to set the number of hours to when the unit goes into...

Page 8: ...ty refit the drainage plug and cap Reconnect the air conditioner to the mains supply and press the POWER button on either the front panel or the remote control The air conditioner will restart and ope...

Page 9: ...ce with a plastic bag Store in a dry place keep it out of the reach of children and take dust control measures Remove the batteries from the remote control FURTHER SAFETY INFORMATION Information on se...

Page 10: ...being changed they shall be fit for the purpose and to the correct specification At all times the manufacturer s maintenance and service guidelines shall be followed If in doubt consult the manufactur...

Page 11: ...pecifications Note The use of silicon sealant may inhibit the effectiveness of some types of leak detection equipment Intrinsically safe components do not have to be isolated prior to working on them...

Page 12: ...3 Evacuate 4 Purge again with inert gas 5 Open the circuit by cutting or brazing The refrigerant charge shall be recovered into the correct recovery cylinders The system shall be flushed with OFN to r...

Page 13: ...covery machine and operate in accordance with manufacturer s instructions 7 Do not overfill cylinders No more than 80 volume liquid charge 8 Do not exceed the maximum working pressure of the cylinder...

Page 14: ...ctrical components are sealed to prevent ignition in the event of a refrigerant release Consult manufacturer if in doubt The recovered refrigerant shall be returned to the refrigerant supplier in the...

Page 15: ...e unit is in direct sunlight Door and windows are open other heat sources are in the room Filters are too dirty Air inlet or outlet is blocked Reposition the unit Close the door and windows and remove...

Page 16: ...ing of the materials used Contact your local authority for details of recycling schemes in your area Made in China PR2 9PP Man Rev 2 0 Main voltage 220 240V 50Hz Rated input power 1350W Power standby...

Reviews: