![Pro-Elec PEL01012 Manual Download Page 3](http://html1.mh-extra.com/html/pro-elec/pel01012/pel01012_manual_1604976003.webp)
3
OPERATION
Wiring the Floodlight
•
Ensure that the mains supply is isolated before commencing installation.
•
A suitable IP rated connector must be used to connect the lead from the floodlight
to the mains supply.
•
Connect the mains cable to the connector. Ensure that the correct polarities for
Live, Neutral and Earth are observed i.e.
- Green/yellow - Earth terminal
- Brown - Live terminal
- Blue - Neutral terminal
•
After wiring, check that there are no stray strands and that all the wires have been
correctly installed.
•
Before connecting power, perform the electrical tests specified in the current
Building and IET Wiring Regulation to ensure that the installation is safe and that
the wiring has been performed correctly.
•
Restore the mains power supply and check that the floodlight illuminates the
required area. Tighten the floodlight using the bolts on the brackets.
Time
Sens
Lux
• Adjusting the PIR Sensor
•
There are three adjustments on the back of the PIR sensor, one adjusts the
duration the floodlight remain lit, the second one is for the sensitivity of movement
detection and the third is to set the level of ambient light before the sensor triggers
the illumination. Some trial and error may be required to set these correctly.
•
Adjust the light level so the floodlight doesn’t activate until the light level is low
enough for floodlighting to be required.
•
Adjust the timer setting for the required duration you require the floodlight to
remain illuminated.
CLEANING & MAINTENANCE
•
Clean the floodlight only with a soft dry cloth. Do not use any chemicals, abrasives
or solvents that could damage the floodlight.
•
The floodlight has a sealed LED lamp and is maintenance free. The LED lamp
cannot be replaced. When the LED lamp reaches the end of its life, the floodlight
will have to be replaced.