background image

3

The floodlight has a beam angle of 120°. It can be tilted at an angle of

approximately 60° and downwards at an angle of approximately 90°.

Note: The angle of adjustment will vary slightly between models.

INSTALLATION

The floodlight is suitable for connection to a 220-240V, 50Hz earthed supply. It is 

designed for permanent connection to fixed wiring, which must be a suitable circuit 

protected by an RCD and an MCB or fuse of the correct rating.

Ensure that the mains supply is isolated before commencing installation.

Before beginning installation, check that you have all the tools you need.

Check that the floodlights and its mains lead are not damaged. If there is any

damage, return it to the place of purchase. Do not attempt to repair it yourself.

Choose the location to fix the floodlight, taking into account the guidance above.

Use the floodlight bracket to mark the position on the fixing holes.

Drill the fixing holes and fix the floodlight into position using the appropriate size

screws and wall plugs (not provided). Check that it is securely fixed.

Connect the main lead from the floodlight to an IP rated junction box. Ensure that

the correct polarities for Live, Earth and Neutral are observed:

- Connect the green/yellow Earth wire to the Earth terminal ‘

E

’.

- Connect the brown Live wire to the Live terminal ‘

L

’.

- Connect the blue Neutral wire to the Neutral terminal ‘

N

’.

After wiring, check that there are no bare wires, all the wires have been correctly

connected and that the cable restraint has been tightened.

Before connecting power, perform the electrical tests specified in the current

building and IET wiring regulations to ensure that the installation is safe and that

the wiring has been performed correctly.

Switch on the electricity to check that the floodlight illuminates. Adjust the angle of

the floodlight so that it illuminates the required area. Tighten the floodlight using

the bolts on the brackets.

Summary of Contents for PEL00500

Page 1: ...1 LED Floodlight with PIR Models PEL00500 PEL00501 PEL00502 PEL00503 ...

Page 2: ...t can be mounted on normally flammable surfaces The floodlight is suitable for use in an ambient temperature between 30 C and 45 C Terminal block not included Installation may require advice from a qualified person POSITIONING This floodlight is suitable for outdoor lighting applications for domestic use only Do not use in areas where an explosive or chemical atmosphere may exist Do not use in are...

Page 3: ... to mark the position on the fixing holes Drill the fixing holes and fix the floodlight into position using the appropriate size screws and wall plugs not provided Check that it is securely fixed Connect the main lead from the floodlight to an IP rated junction box Ensure that the correct polarities for Live Earth and Neutral are observed Connect the green yellow Earth wire to the Earth terminal E...

Page 4: ...sitivity 100 Mode Daylight mode the sensor will work both in the daytime and at night Nightlight mode the sensor will work only at night 50lux Photocell mode the luminary light on automatically at night 50lux Manual override mode keep the light on all of the time Off mode Duration Time 5 10 30 seconds 1 5 10 minutes 20 30 40 minutes 2 5 7 hours Detection Range Max mode 5 7 metres Mid mode 3 5 metr...

Page 5: ...ensitivity max 7m 7m 7m 7m Installation height m 1 8 2 5 1 8 2 5 1 8 2 5 1 8 2 5 Ingress rating IP44 IP44 IP44 IP44 Earthing Class I Class I Class I Class I Max projected area of floodlight mm 130 x 90 180 x 126 210 x 147 260 x 182 Dimensions mm 130 x 90 x 34 180 x 126 x 36 210 x 147 x 37 260 x 182 x 41 Weight 0 37kg 0 58kg 0 77kg 1 58kg INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF ELECTRICAL EL...