 incorpora además una bocina rotable de directividad constante, específicamente diseñada para 

trabajar con un motor de compresión 

Pro DG Systems

 de 50 W RMS. Las características de directividad 

constante de este modelo aseguran poder cubrir 60º de amplitud horizontal y 40º de amplitud vertical (en 

función de su posición), en prácticamente cualquier frecuencia dentro de su radio de acción.  

 
 
 
[

EN

MA 12 

also incorporates a constant rotatable directivity horn specifically designed to work with one 

Pro 

DG Systems

 compression driver of 50 W RMS. Its constant directivity characteristics ensure the ability to 

cover 60º wide horizontally and 40º wide vertically (depending on its position), at virtually any frequency within 

its operational range. 

 

 

 
 

 

 

•   Designed 

 

to 

 

work 

 

with 

 

one 

 

(1) 

 

Pro 

 

DG 

 

Systems

    

    

 

compression driver of 50 W RMS. 

•   Coverage angles of 60º in the horizontal plane and

 

 

    

 

40º in the vertical plane. 

•   Precise directivity control in the pass band. 

•   Cast aluminum construction 

 

 

 
 
 

 

 
 

Throat diameter                                        

25 mm (1 in)

 

 

Horizontal coverage   

                                            90º

 

 

Vertical coverage                       

                            

 

50º  

Cutoff frequency

                                              1.5 kHz 

Construction 

 

 

         

ABS 

Size (WxHxD)

       130.5x130.5x90mm (5.1x5.1x3.5 in) 

Baffle cutout dimension       

104x104mm (4.1x4.1 in)

 

Net weight

                                          0.15 kg (0.33 lb) 

 
 
 
 

KEY FEATURES 

TECHNICAL SPECIFICATIONS 

Summary of Contents for MA 12

Page 1: ...0 An updated pdf version of this manual is always available at www prodgsystems com...

Page 2: ...hnical specifications Thiele Small parameters Mounting information Free air impedance curve Frequency response and distortion Pag 6 7 Caracter sticas principales de la bocina de directividad constante...

Page 3: ...a fuentes emisoras de calor o radiaci n Si el sistema sufre un cambio extremo de temperatura es posible que afecte a su funcionamiento antes de poner en marcha el sistema espere que ste haya adquirid...

Page 4: ...ER LOS SUFICIENTES CONOCIMIENTOS DE USO DEL MISMO Y SIEMPRE RESPETANDO LAS INDICACIONES QUE SE MUESTRAN A CONTINUACION EN ESTE MANUAL ACCESSORIES Do not place the system on a unsteady base that can be...

Page 5: ...gudos cuenta con un motor de compresi n de 1 acoplado a un difusor rotable con cobertura 60x40 MA 12 incorpora un m dulo de amplificaci n Clase D de ltima generaci n y procesamiento propio de uso muy...

Page 6: ...of 1 8 Ohm 50 W High Frequency Cut off 1200 Hz Linkwitz riley 24 filter 18000 Hz Linkwitz riley 24 filter Amplifier included Last generation Class D amplifier with voltage selector 96kHz 24 bit DSP pr...

Page 7: ...l linearity and low harmonic distortion Waterproof cone treatment on both sides of the cone Xmax 6 3 mm Xdamage 30 mm Low harmonic distortion and linear response Nominal diameter 300 mm 12 in Rated Im...

Page 8: ...Maximum Displacement Xmax 6 3 mm Displacement Volume Vd 334 cm3 Voice Coil Inductance Le 1 kHz 1 mH THIELE SMALL PARAMETERS MOUNTING INFORMATION T S parameters are measured after an exercise period us...

Page 9: ...Pro DG Systems compression driver of 50 W RMS Its constant directivity characteristics ensure the ability to cover 60 wide horizontally and 40 wide vertically depending on its position at virtually a...

Page 10: ...aphragm KEY FEATURES ONE UNIT TECHNICAL SPECIFICATIONS MOUNTING INFORMATION Throat diameter 25 mm 1 in Rated impedance 8 ohms Minimum impedance 5 2 ohms 4 kHz D C Resistance 5 6 ohms Power capacity 50...

Page 11: ...10 Note On axis frequency response measured coupled to MA 12 horn in anechoic chamber 1W 1m DIMENSION DRAWINGS FREQUENCY RESPONSE AND DISTORTION FREE AIR IMPEDANCE CURVE...

Page 12: ...ptor de encendido apagado nivel de volumen interruptor de encendido apagado de Bluetooth interruptor TWS interruptor de gesti n DSP pantalla LCD selecci n de presets EN MA 12 incorporates a new Class...

Page 13: ...black powder coating Five steps fixation 17cm each step it includes safety bolt Height 125cm to 195cm 49 21 to 76 77 Max load 32 Kg 70 55 lbs Tube diameter 35mm 1 38 Folded Dimensions 1040x120x120mm...

Page 14: ...incontrolado tornillo de bloqueo para seguridad adicional perno de M20 para un ajuste preciso y vertical Peso 3 86 kg 8 51 lbs EN Distance rod with hand crank and Ring Lock system from K nig Meyer fo...

Page 15: ...1 38x4 72 in Width Adjustable from 310 to 490mm 12 20 19 29 in Max Load 2 x 32 Kg 2 x 70 55 lbs C ncamo para instalaci n en pared o techo Opcional Eyebolt for wall or ceiling installation Optional ES...

Page 16: ...15 Accesorios Accesories ES Disponible de cableado completo del sistema listo para funcionar EN Complete cabling for the system is available and ready to use...

Page 17: ...16 www prodgsystems com...