Pro Charging Systems 1250OB230 Safety, Installation And Operating Instructions Download Page 6

 

 

 

     

 Working in the vicinity of a lead-acid battery is dangerous.  Batteries generate explosive gases 

 

during 

normal operation.  For this reason, it is of the utmost importance that prior to each use of your 

 

charger, you read and follow 

the instructions provided exactly. 

 

    

Il est dangereux de travailler a proximité d’une batterie au plomb.  Les batteries produisent des gaz explosifs en service normal.  Il est 

aussi important de toujours relire les instructions avant d’utiliser le chargeur et de les suivre à la lettre.   

 

    Suitable for servicing only when de-energized. 

Peut faire l

’objet d’un entretien uniquement s’ll est hors tension. 

 

  

 

    

Do Not Expose to Rain. 

NE PAS EXPOSER A LA PLUIE. 

 

Model i4875OB480 only. 

Connection to AC Mains   

This model, designed for use with 480 VAC 60 Hertz, 3 Phase Delta, is provided with an AC power cord - 4xAWG14, 3 Mains + 

Ground.  The green conductor (Earth Ground) is connected directly to the chassis internally.  To connect the charger to AC mains,  
conductors rated 600V 14 AWG 90 DEG C or higher must be used.  Installation must be performed by a certified licensed professional 
electrician.   

For i4875OB480 units supplied with optional AC Plug (NEMA L16-20)   

If already equipped with NEMA L16-20P from the manufacturer, only plug in to a 

grounded

 L16-20 receptacle connected to 480V 60 

Hertz Delta Mains.  Consult a certified licensed professional electrician

.   

 

    

Do nor use with High-Leg Delta Mains supply, this may result in damage to the charger and/or electric 

shock.  Consult a certified licensed professional electrician.

    

   

   

   

   

   

   

  

 

   

   

   

   

   

   

AC Fuse Replacement 

  

Only replace AC input fuses (3 locations located on rear of the unit) with rating of 10A 600V.    

 
CHARGING INDICATIONS 

When your battery charging system is activated, the battery status indicator provides charging information utilizing three red LED 

indicators and one green LED indicator. 

 

    

 

Battery Type Indicators 
Two amber LED indicators are provided to display what type of battery the charger has 
been programmed to charge.  NOTE:  For information on reconfiguring the battery type, 
please contact technical support (615.471.5300) 
 
Battery System Percent Charged Indicators 
Four LED indicators are provided to display the progress of the charge cycle in percentage 
of charge.  Indicators are as follows: 

 

1

ST

 Amber LED . . . .  . . . . . . .  Illuminated configured for Wet Cell and 

AGM*

 batteries 

 

    

2

ND

 Amber LED . . . . . . . . . . . . . Illuminated configured for Gel Cell batteries 

 

    

1

ST 

 RED LED . . . . . . . . . . . . .  Charging - Initial Charging Up To 30%  

 

    

2

ND

 & 3

RD

 RED LEDS  . . . . . . .  Charging - 60% Complete  

 

    

1

ST

, 2

ND

 & 3

RD

 RED LEDS. . . . Charging - 90% Complete  

 

    

BLINKING GREEN LED  . . . .  Finishing Stage (Note: Battery Type Indicator will also blink during this stage)  

 

    

STEADY GREEN LED  . . . . . . Charge Complete 

–Float/Maintenance Mode-On for 5 minutes and off for 60 minutes 

 

    

 

*We normally recommend our STANDARD Delta Volt profile for AGM Batteries.  Always consult with your AGM battery 

manufacturer first regarding charging instructions.  There are some cases where certain AGM batteries are manufactured 
to different specifications and may need a special profile with a much lower finish voltage limitation.  In this case, we will 
do our best to accommodate your unique need. 

 

    

 

   

 

   

    

      

 

   

 

   

    

      

Summary of Contents for 1250OB230

Page 1: ...Charger Models 1250OB 1250OB230 1275OB 4850OB 4875OB 4875OB480 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying AC power to you...

Page 2: ...e 4 General Operation Page 4 5 Charging Indications Page 6 Troubleshooting Page 7 LED Fault Code Indications Page 7 Limited Warranty Information Page 8 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS IMPOR...

Page 3: ...t expose to rain Keep work area well lit 8 Do not overreach Always keep proper footing and balance Do not reach over or across electrical cables or frames 9 Avoid electrical shock To reduce risk of el...

Page 4: ...s recharging instructions Study all battery manufacturers specific precautions such as removing or not removing cell caps while charging and recommended rates of charge When using an extension cord m...

Page 5: ...educe the risk of fire use only on 115 VAC circuits protected by 15 Amperes Branch Circuit Protection for i1250OB 230 VAC circuits provided with 10 Amperes Branch Circuit Protection for i1250OB230 230...

Page 6: ...ger and or electric shock Consult a certified licensed professional electrician AC Fuse Replacement Only replace AC input fuses 3 locations located on rear of the unit with rating of 10A 600V CHARGING...

Page 7: ...ront of the unit is depressed 3 Call technical support for further assistance 615 471 5300 PROBLEM The charge status indicator changes rapidly back and forth from red to green or the green LED will no...

Page 8: ...iginal retail purchaser PCS warrants this battery charger for 18 months including part numbers with the RM designation from the date of retail purchase against defective materials and or workmanship C...

Reviews: