DO NOT attempt to attach a charger to a battery pack if the output of the charger does not match the 
battery pack voltage.  Example: Model i-3625 is a 36 volt output charger and is only usable on 36 
volt battery systems. Charger and battery damage can occur. 

 

Be extra cautious to reduce risk of dropping a metal tool onto battery. It might cause a spark or 

short-circuit a battery or other electrical part, possibly resulting in an explosion. If damaged, contact 
PCS (800.742.2740). 

 
 NEVER charge a frozen battery. 

    

 

Ne jamais charger une batterie gelée. 

 
Assure that the area around your charger and batteries is properly ventilated. Connect your extension cord, with no AC 
Power present, to the battery charger and proceed to plug your extension cord into a 120VAC GFCI protected (Ground Fault 
Circuit Interrupt) outlet. 
 

Risk of electrical shock! Do not touch uninsulated parts of the battery charger output connector, 
battery connector, or battery terminals. 

Once you plug in your PCS battery charging system, the charge cycle will begin automatically. State of charge will be 
displayed by illumination of the Light Emitting Diodes (LEDS) on the battery status indicator located on the front of the unit. 
 

DO NOT disconnect the DC output electrical cord from the battery receptacle when the charger is 
on. The resulting arcing and burning of the plug and receptacle could cause the batteries to 
explode. If the charger must be stopped, first disconnect the AC power supply cord from its outlet, 
then disconnect the charger DC output plug from the battery receptacle. 

We recommend that you leave your system plugged in.  This will reduce sulfation on the lead plates of the batteries and allow 
your PCS charging system to keep your batteries fully maintained and ready to perform at their best. 
 

For Model 2440OB, in order to reduce the risk of fire, use only on circuits provided with 20Amperes                    
Branch Circuit Protection in accordance with the National Electrical Code, ANSI/NFPA 70. 
 
For Model 4836OB, in order to reduce the risk of fire, use only on circuits provided with 30Amperes                    
Branch Circuit Protection in accordance with the National Electrical Code, ANSI/NFPA 70. 

         

Study all battery manufacturers’ specific precautions such as removing or not removing cell caps 
while charging and recommended rates of charge. 

Prendre connaissance des measures de précaution spécifiés par le fabricant de la batterie, p. ex., vérifier s’il faut enlever les 
bouchons des cellules lors du chargement de la batterie, et les taux de chargement recommandés.  
 

 

 

  

Never place the charger directly above or below the battery being charged; gases or fluids from the  

 

   

  battery will corrode and damage the charger.  Locate the charger as far away from the battery as DC 

 

               cables permit. 

 

Ne jamais placer le chargeur directment sous la batterie à charger ou audessus de cette dernière.  Les gaz ou les fluids qui 
sèchappent de la batterie peuvent entrainer la corrosion du chargeur ou l’endommager.  Placer le chargeur aussi loin de la 
batterie qui les cables c.c. le permettent. 
   
 

 

  If it is necessary to remove battery from vehicle to charge it, always remove grounded terminal from  

 

 

  battery first.  Make sure all accesproes in the vehicle are off in order to prevent an arc. 

S’il est nécessaire de retirer la batterie du véhicule pour la charger, toujours d'ébrancher la borne de mise à la masse en 
premier.  S'assurer que le courant aux accessories du véhicule est coupe afin d’éviter la formation d’un arc. 
 
 

 

  Never smoke or allow an open spark or flame in the vicinity of the BATTERY the battery or engine. 

 
Ne jamais fumer près de la batterie ou du moteur et éviter toute étincelle ou flamme nue à proximité de ces dernie. 
 
 
 

 

 Working in the vicinity of a lead-acid battery is dangerous.  Batteries generate explosive gases 

during normal operation.  For this reason it is of the utmost importance that prior to each use of your charger, you 
read and follow the instructions provided exactly. 
Il est dangereux de travailler a proximité d’une batterie au plomb.  Les batteries produisent des gaz explosifs en service 
normal.  Il est aussi important de toujours relire les instructions avant d’utiliser le chargeur et de les suivre à la lettre.   

 

Summary of Contents for 1250OB

Page 1: ...4836OB _______________________________________ 021313 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying AC power to your Pro Charging Systems PCS charger Contact technical support at PCS with any product installation or service questions 800 742 2740 Pro Charging Systems LLC LaVergne TN 37086 3539 ...

Page 2: ...ty and operating instructions for future reference CONCERVER CES INSTRUCTIONS CE MANUEL CONTIENT DES INSTRUCTIONS IMPORTANTES CONCERNANT LA SÉCURITÉ ET LE FONCTIONNEMENT Understand and relate the Hazard Levels and Signal Words utilized in this manual with the following definitions This symbol means Immediate hazards which will result in severe personal injury or death This symbol means Hazards or ...

Page 3: ...ose to rain Keep work area well lit 8 Do not overreach Keep proper footing and balance at all times Do not reach over or across electrical cables or frames 9 Avoid electrical shock To reduce risk of electrical shock unplug charger from outlet before attempting any maintenance or cleaning 10 Do not operate charger with damaged electrical cord or plug To reduce risk of damage to the electrical plug ...

Page 4: ...anufacturers specific precautions such as removing or not removing cell caps while charging and recommended rates of charge When using an extension cord make sure that pins on plug of extension cord are the same number size and shape as those of the charger s plug that extension cord meets UL Underwriters Laboratories Inc acceptance that wire size is large enough for AC ampere rating of charger Al...

Page 5: ...order to reduce the risk of fire use only on circuits provided with 30Amperes Branch Circuit Protection in accordance with the National Electrical Code ANSI NFPA 70 Study all battery manufacturers specific precautions such as removing or not removing cell caps while charging and recommended rates of charge Prendre connaissance des measures de précaution spécifiés par le fabricant de la batterie p ...

Page 6: ...t is only flowing to the battery system for 5 minutes and then current will stop completely for 60 minutes Your system provides an equalization stage every 30 days while plugged in If the charger is normally disconnected from A C after completing charge equalization can be accomplished by plugging back into A C whenever this stage is desired Battery manufacturers recommend that equalization is don...

Page 7: ...Charging Systems LLC PCS makes this Limited Warranty only to the original retail purchaser PCS warrants this battery charger for three years unless the serial number ends with a suffix of RM or CR from the date of retail purchase against defective materials and or workmanship RM suffix refers to Restricted Markets such as Rental applications and Heavy Industrial applications and designates the war...

Page 8: ...8 ...

Reviews: