PRO Charging System i1215BSBDUAL Safety, Installation And Operating Instructions Download Page 7

 
On single bank systems, simply try the charger on another battery.  If the charger now operates normally 
(steady red LEDs or changes to green and holds), this indicates a possible problem with the original 
battery. 
 
If the same bank continues to malfunction, please call our technical support group (800.742.2740). 
 

PROBLEM: A green LED was illuminated before disconnecting the power from the charger, but 
upon reconnection, red LEDs appear and remain on. 

 
Solution Sequence:  This is normal operating procedure for the system and simply indicates that a re-
analysis of the battery status has been initiated and after a series of steps, the green LED will illuminate. 
 

PROBLEM: Two red LED indicators flashing. 

 
Solution Sequence:  This indicates a Forming Stage timeout and alerts the user that the battery voltage 
has not risen above an acceptable limit within 3 hours.  Battery should be tested. 
 

PROBLEM: Three red LED indicators flashing. 

 
Solution Sequence: 

 

This indicates that the charger has exceeded the maximum amount of time allowed 

for charging the battery.  Battery should be tested.

 

 

PROBLEM: Four red LED indicators flashing. 

 
Solution Sequence:  This indicates that the internal temperature of the charger has exceeded allowable 
limits and this bank of the charger has shut down.  If charger is in a closed compartment, open 
compartment doors and allow charger to cool for 8 hours.  After this period, connect the charger to AC 
and begin charging again. 

 

LIMITED WARRANTY 

 
Pro Charging Systems, LLC (PCS) makes this Limited Warranty only to the original retail purchaser.   
PCS warrants this battery charger for three years (unless the charger is used in a Restricted Market) from 
the date of retail purchase against defective materials and/or workmanship.  Restricted markets include 
markets outside of the USA, Rental applications and Heavy Industrial applications.  Sometimes RM is 
designated in the PCS Part number when ordered, but is not part of the model number.  Chargers used in 
Restricted Markets will have a warranty period of 18 months from the date of retail purchase against 
defective materials and/or workmanship.  CR refers to “Certified Reconditioned” and designates a 1 year 
warranty.    If such defects should occur, this unit will either be repaired or replaced at the discretion of 
the manufacturer.  It is the responsibility of the original purchaser to return the charger along with proof of 
purchase, transportation, and/or any mailing or handling charges prepaid to the manufacturer or its 
authorized representative.  Chargers that are purchased more than two years beyond the date of 
production will automatically have a warranty start date that will be the two year anniversary of the 
production date. 
 
This limited warranty is void if the product is misused, improperly maintained, handled carelessly or 
incorrectly operated.  Additionally, this warranty is void if the charger is disassembled, the charger’s 
charge cables are cut, the power cord is cut off, the charger is altered without authorization from PCS, the 
serial number is removed, or repair is attempted by anyone other than an authorized representative.  PCS 
makes no other warranty other than this limited warranty and expressly excludes any implied warranty, 
including warranty for any incidental or consequential damages.  This is the only expressed limited three 
year warranty authorized by PCS and does not authorize anyone to assume or make any other obligation 
towards the product other than this three year Limited Warranty.  Some states do not allow limitation of 
incidental or consequential damages. 
 
This warranty gives you specific legal rights and you may also have other rights which vary from state to 
state.  Please call Pro Charging Systems, LLC for full warranty information and/or service please call 
(800.742.2740).   
 

 

Summary of Contents for i1215BSBDUAL

Page 1: ..._______________________________________ 070914 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying AC power to your Pro Charging Systems PCS charger Contact technical support at PCS with any product installation or service questions 800 742 2740 Pro Charging Systems LLC LaVergne TN 37086 3539 ...

Page 2: ... and installation instructions before installing or applying AC power to your on board battery charging system Please contact us with any product installation or service questions at technical support 800 742 2740 INTRODUCTION Pro Charging Systems LLC PCS has been manufacturing high quality high performance charging systems since 1989 Our charging systems are designed and built tough to withstand ...

Page 3: ...f battery Review all cautionary markings on any product being utilized in or around the charging device PERSONAL PRECAUTIONS Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing eyes or other surfaces Wear complete eye protection and clothing pro...

Page 4: ... guidelines in this manual to install your fully automatic PCS battery charging system Assure that the area around your charger and batteries is properly ventilated Connect your extension cord with no AC power present to the battery charger and proceed to plug your extension cord in at a nearby 120VAC outlet Once you plug in your PCS battery charging system your batteries will be simultaneously an...

Page 5: ... compartment wall is chosen make certain its strength is adequate to support the weight of the charger Use the mounting flanges of the charger to mark locations for starter holes Drill a 1 16 inch hole at each marked location Then utilize all stainless steel screws that have been provided and install the charger securely being cautious not to over tighten the screws Silicon sealer should be used t...

Page 6: ...should now observe a red LED indication on each bank of the charger representing each individual battery being charged The voltage of each battery will reflect the number of LED indicators illuminated When charging is complete remove the extension cord from the 120VAC outlet first and then unplug the charger TROUBLE SHOOTING PROBLEM No LED indicators illuminate in any of the charger banks Solution...

Page 7: ...ntal applications and Heavy Industrial applications Sometimes RM is designated in the PCS Part number when ordered but is not part of the model number Chargers used in Restricted Markets will have a warranty period of 18 months from the date of retail purchase against defective materials and or workmanship CR refers to Certified Reconditioned and designates a 1 year warranty If such defects should...

Page 8: ...Below are some of our other options in chargers and battery accessories Call our technical support group for more detailed information or visit our web site www pcsdv com www pcsdv com 8 ...

Reviews: