pro bel VISTEK V6301 User Manual Download Page 5

VISTEK V6301 audio  
wordclock distribution amplifier

 

 

 

 

 

HU-V6301

 

 

 

       

5

 

 

 

Table 2.1.1 

 

Description of V6301 rear panel connections for standard rear panels 

 

SIGNAL 

SOURCE 

                     COMMENTS 

POWER 

Rack PWR Header 

+15V at 100mA  (1.5W max) 

DART bus 

Rack DART header 

Vistek DART Rack controller 

W/CLK A(IN) 

W/CLK ext. source 

Ch. A TTL wordclock input:  
 

 
 

 

75 

Ω

/Hi-Z single ended on BNC rear panel 

 

 

75 

Ω

 /Hi-Z single ended on screw terminal rear panel 

W/CLK A1 (OUT) 

V6301 DA 

Ch. A  TTL wordclock outputs  (all modes) 

W/CLK A2 (OUT) 

 

75 

Ω

 /Hi-Z single ended on BNC rear panel 

W/CLK A3 (OUT) 

 

75 

Ω

 /Hi-Z single ended on screw terminal rear panel 

W/CLK A4 (OUT) 

 

 

W/CLK B(IN) 

W/CLK ext. source 

Ch. TTL wordclock input sourcing cable length up to 50m 
75 

Ω

 single ended on BNC rear panel 

 
 

 

75 

Ω

 /Hi-Z single ended on BNC rear panel 

 

 

75 

Ω

 /Hi-Z single ended on screw terminal rear panel 

W/CLK B1/A5 (OUT) 

V6301 

1:8 mode: Ch A wordclock o/p.    

W/CLK B2/A6 (OUT) 

 

2:4 mode: Ch B wordclock o/p 

W/CLK B3/A7 (OUT) 

 

75 

Ω

 /Hi-Z single ended on BNC rear panel 

W/CLK B4/A8 (OUT) 

 

75 

Ω

 /Hi-Z single ended on screw terminal rear panel 

 

2.2 

Input Impedance Selection 

 
The input impedance of the A Channel and B Channel wordclock receivers may be set to either 75 ohms  or 
high impedance  (

 10k 

Ω

)  by means of jumpers LK3 and LK5.   The high impedance function may be used 

when it desired to daisy-chain the inputs of a number of V6301 DA’s in a rack, without cascading them.  In 
this case  one of the V6301s is set for 75 ohms and the others are set to high input impedance.  Two 
cautions are advised: 
 

• 

The V6301 with 75 impedance should be the V6301 physically farthest from the feeding source. 

• 

The daisy chaining is intended to be used within a rack or cabinet.  Long cable runs into high impedance 
are NOT recommended.  When daisy chaining V6301s with Hi-Z inputs, source cable length should not be 
more than a couple of meters. 

 

Impedance option 

Jumpers 

Channel A     75 

Ω

    

LK3 CLOSED 

Channel A      Hi-Z   (>10k 

Ω

LK3 OPEN 

Channel B     75 

Ω

 

LK5 CLOSED 

Channel B      Hi-Z   (>10k 

Ω

LK5 OPEN 

 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for VISTEK V6301

Page 1: ...1 VISTEK V6301 AUDIO WORDCLOCK DISTRIBUTION AMPLIFIER USER GUIDE www pro bel com...

Page 2: ...plifier 2 Issue 1 Contents 1 DESCRIPTION 3 2 INSTALLATION 4 2 1 Rear Panel Connections 4 Table 2 1 1 5 2 2 Input Impedance Selection 5 2 3 DA Mode 6 3 OPERATION 7 3 1 Front Panel 7 3 2 LED Indications...

Page 3: ...either the balanced rear module or the unbalanced BNC module Two families of passive rear panel module are available TTL inputs and outputs with screw terminals This rear panel provides for a 2 4 or...

Page 4: ...and the ground to the S terminal outer GND on BNC s Grounds screens are connected to chassis on all outputs and inputs 1U panels are similarly marked and details for the standard rear panel options a...

Page 5: ...B2 A6 OUT 2 4 mode Ch B wordclock o p W CLK B3 A7 OUT 75 Hi Z single ended on BNC rear panel W CLK B4 A8 OUT 75 Hi Z single ended on screw terminal rear panel 2 2 Input Impedance Selection The input i...

Page 6: ...Channel B input Bout switch sources the 4 Channel B outputs from either the Channel A input or the Channel B input The source channel for each of the Aout and Bout switches is indicated by an A or B...

Page 7: ...s front panel indicators as shown above A red ERROR LED for each channel indicates no signal on the W CLK input The REM LED flashes to indicate a DARTbus access is in progress The green V LED is lit w...

Page 8: ...Bout groups have their sourcing controlled by DART The switches may be changed at any time and the table below shows the possible combinations Aout switch Bout switch Mode A A 1 8 mode Aout Ain Bout A...

Reviews: