  Digital Video Non-reclocking DA 

2

Configuration and operation

2.1

Selecting the rear connector

The 3404 may be used with either the 20mm K3404.2 rear connector providing five
outputs or the 30mm K3404.3 rear connector providing ten outputs. Only the first
five, non-inverting outputs can be used for ASI.  (Although many products can cope
with ASI if it is inverted, this cannot be guarenteed).  A third option of rear panel is
the K3400.2M.  This has a BNC input and 10 SMB outputs and is only 20mm wide. 
This is supplied with ten 1.6m long SMB-BNC cables for easy interconnection to other 
equipment with BNC connections.

Please refer to the installation chapter for help with installing modules and rear
connectors into the ICON frame.

Technical Manual                                                                                                                  3

POWER

P

3404

RSF1

The 3404 SDI/SDTI/ASI/MADI  distribution amplifier

K3404.2

SDI/ASI

OUT

SDI/ASI IN

I

N
P

U

T
S

K3404.3

SDI/ASI IN

SDI/ASI

OUT

SDI

OUT

Five
non-inverted 
outputs for
ASI or SDI

Five inverted 
outputs for
SDI only

K3400.2M

OUT

 IN

I

N
P

U

T
S

OUT

OUT

OUT

OUT

OUT

OUT

OUT

OUT

OUT

Summary of Contents for ICO-3404-2000

Page 1: ...duction 2 2 Configuration and operation 3 2 1 Selecting the rear connector 3 2 2 Trouble shooting 4 3 Status monitoring 5 4 Specification 6 5 Ordering information 7 Technical Manual 1 Digital Video No...

Page 2: ...DTI ASI and MADI The features available are five outputs with the 20mm K3404 2 rear connector ten outputs with the 30mm K3404 3 rear connector ten outputs with the 20mm K3400 2M five outputs are DVB A...

Page 3: ...is the K3400 2M This has a BNC input and 10 SMB outputs and is only 20mm wide This is supplied with ten 1 6m long SMB BNC cables for easy interconnection to other equipment with BNC connections Please...

Page 4: ...nals The Power LED is not lit check mains power to the frame is turned on if necessary check the PSU as explained in the power supply section check the card is plugged in securely check to see if the...

Page 5: ...to the COSMOS status monitoring controller if fitted module present module type module bar code module issue no For further details of the Pro Bel status monitoring system please refer to the COSMOS s...

Page 6: ...n be used with ASI format signals Impedance 75W unbalanced Performance Input return loss 15dB to 300MHz 12 5dB to 400MHz Max output level 800mV into 75W load Output return loss 15dB to 300MHz 12 5dB t...

Page 7: ...art number Description ICO 3404 2000 5 output non reclocking SDI ASI DA 20mm ICO 3404 3000 10 output non reclocking SDI DA 30mm ICO 3404 2M00 10 output SMB non reclocking SDI DA 20mm Issue 2 7 Digital...

Reviews: