![Prizma PRIZSPA SALTFX-PRO User Manual Download Page 6](http://html1.mh-extra.com/html/prizma/prizspa-saltfx-pro/prizspa-saltfx-pro_user-manual_1603748006.webp)
Installation
1.
Choose appropriate position for halogenerator on wall between clean room and salt room.
Center of the outlet hole should be about
ϰΖϲΗ
above floor level.
2.
Drill a 110 mm diameter hole for outlet in the wall, between clean room and salt room.
3.
Put halogenerator against drilled 110 mm hole. Mark 4 holes for anchors (holes are at rear
side of halogenerator case) and remove halogenerator from the wall.
4.
Drill four 8mm diameter holes for nylon anchors, and insert the anchors into the holes.
5.
Mount the halogenerator on the wall selecting four 5.5x60mm-‐DIN7997 metal screws.
6.
Insert power cable to power plug and connect to earthed mains power inlet.
Note: Mains power outlet used for connection of the halogenerator to the mains shall be
easily reachable to the operator.
Installation
Clean room
Salt room
Wall
Halogenerator
Outlet
hole
Power plug
Ventilation/light
control plug
Fuse holder
Main switch