Page 2 of 2
11775 E. 45th Ave. Denver, CO 80239 Ph: 1-800-880-1180 Fax: 303-695-7633
INSTALLATION INSTRUCTIONS
PZM-WW40 -100/277V-RGBW & PZM-WWA40X -100/277V-RGBW
SĒNIK
A40 & A40X ARRAY RGBW
100-
277V
Prizm
™
is a trademark of American Lighting, Inc. ©2020 www.PrizmLighting.com REV2038
FIGURE 2
FIGURE 3
OPERATING RGBW WALL WASHER:
This fixture does not have a standalone mode and
requires the use of an external DMX 512 control.
4 Channels
RDM (REMOTE DEVICE MANAGEMENT):
This fixture has RDM functions. RDM is the protocol which supports two-way traffic
in standard DMX512. Configure and monitor the fixture along with the capability to
change the DMX address and DMX mode. Every fixture with RDM can be recognized
by a built-in UID code.
Attached mounting
bracket
FUNCTION
DMX
VALUE
SETTING
4-CH
RED
000-255
0-100%
1
GREEN
000-255
0-100%
2
BLUE
000-255
0-100%
3
WHITE
000-255
0-100%
4
PARAMETER ID
DISCOVERY
COMMAND
SET
COMMAND
GET
COMMAND
DISC_UNIQUE_BRANCH
*
DISC_MUTE
*
DISC_UN_MUTE
*
DEVICE_INFO
*
SOFTWARE_VERSION_LABEL
*
DMX_START_ADDRESS
*
*
IDENTIFY_DEVICE
*
*
SUPPORTED_PARAMETERS
*
SENSOR_DEFINITION
*
SENSOR_VALUE
*
DMX_PERSONALITY
*
*
DMX_PERSONALITY_DESCRIPTION
*
INSTALLING WALL WASHER (SEE FIGURES 3 & 4):
1. Loosen the tilt/angle adjustment bolt to rotate the light to get
access to the mounting brackets.
2. Use the through-mounting holes in the brackets of each unit
(See FIGURE 2) and attach to structurally sound surface using
suitable fasteners. Ensure the location of each fixture is within
wiring distance of conjoining fixtures and that the first fixture in the
series is within wiring distance of controller.
3. Connect conjoining fixtures together by connecting the male and
female cord ends to each other, then turning clockwise until the
connection is secured. See Figure 3. Use PZM-WW-JUMP#-BK to
increase the distance between fixtures. See Figure 3.
4. Ensure the last fixture in the series has a termination end cap
(PZM-WW-SIGEND6PIN) attached to the tail wire (female end).
5. Connect the first fixture in the series to a DMX control system
using PZM-WW-PSL-15FT (power + signal cable) and
PZM-WW-XLR3-XLR5 (XLR3 to XLR5 adapter).
6. Plug first fixture in the series into grounded 120V AC receptacle
using PZM-WW-PSL-15FT (power + signal cable).
FCC Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
FCC WARNING
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to
operate the equipment.