PRIZM 201750 Series User'S Manual And Troubleshooting Manual Download Page 5

Moog Components Group    

201750-xxx MM2/Mini4 10/100 

Feb 24, 2009 

Ethernet Daughterboard Manual, Rev B 

 

Page 5 of 8 

 

 

 

Diagnostics connector (J6).  

NOTE: DIAGNOSTICS NOT AVAILABLE

 

D4 (Green) 

Located at the lower right edge of the board serves as an indicator that the microprocessor is 
receiving diagnostics requests from the diagnostics PC through the Diagnostics Header (J4) 
or  Diagnostics  connector (J6).    This  LED  will  blink  ON  with  a  received  request  then  OFF 
with the next request.  

NOTE: DIAGNOSTICS NOT AVAILABLE

 

D5 (Green) 

Labeled ‘Q_OF’, located on the center top edge of the board, if “OFF” provides an indication 
that the Ethernet to serial chip U8 is overflowing its internal buffer.  Typically this LED will 
always be “ON” – not in an error state. 

D6 (Green) 

Labeled  ‘LOCAL’,  located  on  the  center  top  edge  of  the  board,  if  “ON”  provides  an 
indication  that  the  programmable  logic  device  U1  is  receiving  a  system  receive  clock  and 
receiving data from the Daughterboard Header (J2).  

D7 (Green) 

Labeled  ‘REMOTE’,  located  on  the  center  top  edge  of  the  board,  if  “ON”  provides  an 
indication  that  the  programmable  logic  device  U1  is  receiving  a  system  transmit  clock  and 
outputting data onto the Daughterboard Header (J2).  

D9 (Green) 

Labeled ‘+3.3V’, located at the bottom right edge of the board serves as an indicator that the 
on-board +3.3VDC power supply (U6) is working. 

D10 (Green) 

Labeled ‘W_TX’, located on the center top edge of the board, if “ON” provides an indication 
that the programmable logic device U1 is receiving data from the Ethernet to serial chip (U8) 
and outputting data onto the Daughterboard Header (J2).  

D11 (Green) 

Labeled ‘W_RX’, located on the center top edge of the board, if “ON” provides an indication 
that the programmable logic device U1 is receiving data from the Daughterboard Header (J2) 
and sending it to the Ethernet to serial chip (U8).  

D12 (Green) 

Labeled “P5 LED1”, located at the lower right edge of the board serves as an indicator that 
data is being sent between the Ethernet Switch chip (U4) and the Ethernet to serial chip (U8).  

NOTE: THIS FUNCTION IS NOT AVAILABLE

 

D13 (Green) 

Labeled “P5 LED2”, located at the lower right edge of the board serves as an indicator that 
data is being sent between the Ethernet Switch chip (U4) and the Ethernet to serial chip (U8).  

NOTE: THIS FUNCTION IS NOT AVAILABLE

 

D14 (Green) 

Labeled “P5 LED3”, located at the lower right edge of the board serves as an indicator that 
data is being sent between the Ethernet Switch chip (U4) and the Ethernet to serial chip (U8).  

NOTE: THIS FUNCTION IS NOT AVAILABLE

 

 

Bottom of Board 

LED 

Indication 

D8 (Green) 

Located  at  the  bottom  left  edge  of  the  board  serves  as  an  indicator  that  the  LED  display 
header is powered. 

 

CONNECTORS AND HEADERS:  

 

J1 

         ISP Header 

Summary of Contents for 201750 Series

Page 1: ...Troubleshooting Guide February 24 2009 Revision B Moog Components Group Springfield Operations 750 West Sproul Road Springfield PA 19064 E Mail mcg moog com URL www moog com components Tel 610 328 40...

Page 2: ...THERNET DAUGHTERBOARD P N 201750 XXX 3 1 1 10 100 ETHERNET INTERFACE 3 1 2 MM2 MINI4 10 100 ETHERNET DAUGHTERBOARD REVISION HISTORY 4 1 3 MM2 MINI4 10 100 ETHERNET DAUGHTERBOARD DASH NUMBER DEFINITION...

Page 3: ...ets and flows the packets serially through the MM2 Mini4 daughterboard connector at a synchronous data rated defined by the MM2 16Mbps or Mini4 25Mbps The 100Mbps Ethernet data rate is approximately 4...

Page 4: ...right LED yellow will be lit solidly if an Ethernet link is detected and blink off with traffic All four ports are also auto polarity correcting so either straight or crossover cables can be used NOTE...

Page 5: ...of the board serves as an indicator that the on board 3 3VDC power supply U6 is working D10 Green Labeled W_TX located on the center top edge of the board if ON provides an indication that the progra...

Page 6: ...o 10 SPEED_P2_LED ACT_P3_LED 11 o o 12 SPEED_P3_LED ACT_P4_LED 13 o o 14 SPEED_P4_LED NO CONNECT 15 o o 16 NO CONNECT NO CONNECT 17 o o 18 NO CONNECT NO CONNECT 19 o o 20 NO CONNECT NO CONNECT 21 o o...

Page 7: ...CE F2 1 5 Amp PTC 5VDC input fuse for Daughterboard header at J2 F3 1 5 Amp PTC 5VDC output fuse for LED header at J12 DO NOT PLACE SWITCHES There are no switches on this board TRIMPOTS There no trimp...

Page 8: ...al Rev B Page 8 of 8 1 7 MM2 Mini4 10 100 Ethernet Daughterboard Power Requirements The 10 100 Ethernet daughterboard uses approximately 330mA 5VDC 1 8 MM2 Mini4 10 100 Ethernet Daughterboard Dimensio...