PRIZM 201640 series User'S Manual And Troubleshooting Manual Download Page 5

Moog Components Group 

4 Port 10/100/1000 Mbps Ethernet Switch 

February 23, 2009

 

(201640-xxx) 

 

Page  5 of 13 

 

1.4

  4 Port 10/100/1000 Mbps Ethernet Switch Indicators and Controls 

LEDS:    There  are  7  surface  mount  (SMD)  and  4  dual  through  hole  LED  indicators  on  the  4  Port 
10/100/1000  Mbps  Ethernet  Switch.    In  addition,  there  are  8  LED  indicators  that  are  built  into  the  4 
position RJ-45 connector.  The function of each of these LEDs is detailed below:   

All LEDs are located on the topside of the 4 Port 10/100/1000 Mbps Ethernet Switch. 

 

LED 

Indication 

D1 

Labeled ‘1.2V’, surface mount, located in the middle of the top edge of the board.  
This LED is non-functional and does not need to be illuminated for the board to 
function properly. 

D2 

(Green/Green) 

A dual LED located on the top edge of the board next to the optical module.  The 
top LED, labeled PWR, provides an indication that the power supply to the optical 
transceiver is operational.  The lower LED, labeled FBR, indicates that the optical 
transceiver module has detected the presence of an input signal on the fiber link. 
When ‘ON’ indicates that this board has a good level of received optical power 
from the remote unit. 

D3 

(Green/Green) 

A dual LED located on the top edge of the board next to the optical module.  The 
top LED, labeled  LNK, provides an indication that the onboard MAC and PHY 
are  communicating  properly.    The  lower  LED,  labeled  DUP,  should  be 
illuminated at all times to indicate that the optical link is functioning in full duplex 
mode. 

D4 

(Green/Green) 

A  dual  LED  located  in  the  upper  left  corner  of  the  board  next  to  the  RJ-45 
Ethernet connector.  The top LED, labeled DUP1, is illuminated if Port 1 of the 
Ethernet  Switch  is  connected  in  full  duplex  mode.    The  lower  LED,  labeled 
DUP3, is illuminated if Port 3 of the Ethernet Switch is connected in full duplex 
mode. 

D5 

(Green/Green) 

A  dual  LED  located  in  the  upper  left  corner  of  the  board  next  to  the  RJ-45 
Ethernet connector.  The top LED, labeled DUP2, is illuminated if Port 2 of the 
Ethernet  Switch  is  connected  in  full  duplex  mode.    The  lower  LED,  labeled 
DUP4, is illuminated if Port 4 of the Ethernet Switch is connected in full duplex 
mode. 

D7 (Green) 

Labeled ‘2.5V’, surface mount, located on the mid-right of the board. When ‘ON’ 
indicates the on-board 2.5V converter is operational 

D8 (Green) 

Surface mount, located in the middle of the bottom edge of the board.  Indicates 
that power is being delivered to the Display Board Header (J7). 

Summary of Contents for 201640 series

Page 1: ...l And Troubleshooting Guide February 23 2009 Rev C Moog Components Group Springfield Operations 750 West Sproul Road Springfield PA 19064 E Mail mcg moog com URL www moog com components Tel 610 328 40...

Page 2: ...Mbps Ethernet Switch Dash Number Definitions 3 1 3 4 Port 10 100 1000 Mbps Ethernet Switch Operation 3 1 4 4 Port 10 100 1000 Mbps Ethernet Switch Indicators and Controls 5 1 5 4 Port 10 100 1000 Mbps...

Page 3: ...Moog Components Group technical support if you have questions about these or any other features that may be required 1 1 4 Port 10 100 1000 Mbps Ethernet Switch Revision History The 4 Port 10 100 1000...

Page 4: ...smitter for delivery to the switch at the opposite end of the link The receive portion of the 4 Port 10 100 1000 Mbps Ethernet Switch accepts the optical signal from the remote end of the link and rec...

Page 5: ...of received optical power from the remote unit D3 Green Green A dual LED located on the top edge of the board next to the optical module The top LED labeled LNK provides an indication that the onboard...

Page 6: ...D LED This LED will be illuminated GREEN if Port 2 is communicating at 1000Mbps and ORANGE if the port is communicating at 100Mbps If this LED is not illuminated but the LINK LED is lit the port is co...

Page 7: ...switches on the 4 Port 10 100 1000 Mbps Ethernet Switch CONNECTORS The user accessible connectors on the 4 Port 10 100 1000 Mbps Ethernet Switch are as follows J2 Power Diagnostics RT 1 o o 2 RT GND...

Page 8: ...UPLEX Predominately HIGH if Port 1 is operating in HALF DUPLEX In half duplex mode the pin will go LOW temporarily to indicate COLLISIONS on PORT 1 5 PORT2 LINK LOW if Port 2 is connected to a valid E...

Page 9: ...LOW if PORT 2 is operating at 1000Mbps HIGH otherwise 17 PORT3 100 LOW if PORT 3 is operating at 100Mbps HIGH otherwise 18 PORT3 1000 LOW if PORT 3 is operating at 1000Mbps HIGH otherwise 19 PORT4 10...

Page 10: ...k Lengths up to 20 kilometers with single mode up to 1 kilometers with multimode Onboard Data Channels Number of Data Channels 4 x Gigabit Ethernet Ethernet Data Rates 10 100 or 1000Mbps Off board Dat...

Page 11: ...e board if 5VDC is not available Verify 3 3VDC across C77 If 3 3V is not available replace the board with a spare If 3 3V is available check the display LED D9 If only the 2 5V Power LED is out Verify...

Page 12: ...ata bit on the back plane NOTE The diagnostics feature in no way interferes with normal operation of the modem it is not necessary to be running the diagnostics s w for the modem to work 1 9 Communica...