Prismasonic Cinomorph P-100R Setup Instructions Download Page 2

Anamorphic Lens

Cinomorph P-100R

Setup Instructions

Setup Instructions

Setting up the system:

STEP 4 

Make sure the projector is turned on. It is helpful 
to have a picture that fills the entire panel of 16:9 
projector. With a 2.40:1 source material the 
vertical expand is good to be performed to the 
picture at this step. 

(Fig 4)

Now carefully adjust the focus of projector. Also 
make sure the image is symmetrically in the 
center of the 2.40:1 screen.

STEP 5

 

First move the prisms to the ‘

pass

’ mode using 

the supplied 

remote controller

 until the prisms 

stop. Carefully position the lens with a stand in 
front of the projector, with the small opening 
closest to the projector lens and the large 
opening pointing towards the screen. 

Now manually adjust the lens in a stand. Make 
sure the entire beam fits centered within the 
two lenses 

(Fig 5).

 Lower, raise and tilt the lens 

until the desired height and angle is reached. 
Make sure the image is now rectangular and still 
symmetrically in the center of the screen.

NOTE: 

The optimum symmetry for the projected 

picture can only be found by tilting the lens to the 
direction of the beam

Fig 4

Fig 5

STEP 9 

In case the friction based lens height 

(Fig 9-a)

 or 

the tilt 

(Fig 9-b)

 adjusting mechanism become too 

loose, it is possible to get them tightened with the 
set screws of stand drums on both sides of lens. 
Use the 

L-wrench, 4 mm

 for tightening the 

screws.

You’re done.

 Enjoy your new 2.40:1 picture!

STEP 6 

Using the remote control, press ‘

wide

’ until the 

prisms stop again. The tuning of picture width can 
be accomplished manually by adjusting the 

cap 

screws

 inside the lens to match your screen 

perfectly on both sides. 

NOTE: 

Tuning is done with the cap screws to where the 

prisms stop after turning the prisms to the

 

‘wide’ 

position

 

(Fig 6)

Fig 6

rear view

front view

STEP 8 

Take the front element, remove the cover sheets 
and secure it to the lens body using the four 
screws 

(Fig 8)

You slightly have to 

zoom in

 the picture after 

front element installation. Also 

now adjust the 

focus

 and picture in a 

‘wide’

 mode to achieve 

the optimum settings, and note these settings 
as for future reference.

Fig 8

Fig 9

a)

b)

Only use optically safe lens cleaning solutions and a clean, 
lint-free cloth certified for cleaning of lens materials. In 
order to clean the optics from both sides, the bottom plate 
can be temporarily removed.

Fig 7

rear view

front view

STEP 7 

If the sides of picture are not opening/closing synchronously to each other when switching the modes, tune 
the terminal screws to where the prisms stop after pressing the ‘

pass

’ button 

(Fig 7)

. Open the cap screw of 

the prism which had a shorter travel, and close the cap screw of that prism, which had a longer travel until 
both sides of picture are opening and closing synchronously to each other.

Cleaning the optics:

Maintenance:

Your Cinomorph lens was designed to require very minimal cleaning. It is best to only wipe the lens housing 
with a clean, damp, soft cloth when needed.

Anamorphic Lens

Cinomorph P-100R