Product Specifications and Warnings 

 
 
Please read this manual prior to use. 

 

 

This product is intended for professional use only.  

 

This product is designed for damp conditions, but is not suitable for wet locations.  

 

Due to risk of injury the safety cable MUST be attached while the product is suspended. 

 

The product requires the appropriate power supply. (90-264 VAC, 47-63 Hz) 

 

It is not intended for use on dimming circuits.  

 

Contact Prism Projection Service and Support prior to any service work or the product warranty may be 
voided.  

 

 

Basic Installation

 

 

Before installing this product please make sure that you have read all warnings and safety information provided 
in this manual. 
 
The product must be installed in a suitable manner to support the product weight and with the safety cable  
attached in such a way that it cannot be removed without releasing the clip. The safety cable should be attached 
at all times during both installation and removal of the product.  
 

 
Safe Mounting  

 
Always install the safety cable provided when mounting the product overhead. To install, loop the safety cable 
through the yoke and the support structure and clip the carabineer to the safety cable. Make sure that the loop 
cannot slip off the support structure. 
 
 

Attaching Data and Power Cables 

 
Note: This lighting fixture can be used individually or modules can be daisy chained. In a chain of fixtures each 
module can be individually addressed, or each can have its own address wherein each fixture is independent of 
the others. 

 
Step 1: If needed attach an appropriate connector to the end of the power cord included with the product. Any 
connector you attach to the end of the product must be rated for 15 Amperes and 250VAC, and of the grounding 
type. The conductors in the power cable are color coded for ease of assembly. 
 
Wire Color 

 

 

 

Conductor Function 

Green or Green with Yellow Stripe 

GROUND  

Blue 

or 

White 

   NEUTRAL 

Brown 

or 

Black 

   LINE 

 
 
 
 

Summary of Contents for RevEAL Studio3

Page 1: ...RevEAL Studio3 User Manual April 2013 Prism Projection Inc 3 User Manual...

Page 2: ...moved without releasing the clip The safety cable should be attached at all times during both installation and removal of the product Safe Mounting Always install the safety cable provided when mounti...

Page 3: ...iring Do not exceed recommended cable lengths or number of receivers on a chain Care and Maintenance It is recommended that care always be exercised when handling the fixture It contains electronic co...

Page 4: ...the fixture as illustrated below The Navigation Buttons can be used to access control settings and display fixture status on the Navigation Screen Power O Switch Con Intensity or CCT Adjustment Knob...

Page 5: ...dress Screen Use this screen to select either DMX address 1 512 or Art Net universe 0 0 to 15 15 and to choose either 8 or 16 bit encoding The screen displays the fixture IP and MAC address at the bot...

Page 6: ...xture from this screen will save the last fixture settings including intensity and color TrueSource Screen This screen displays the CIE value of the color of the light being produced by the fixture Th...

Page 7: ...ngs Energy Full Eco Channel Personality Advanced Settings Refresh Rate Advanced Settings Algorithm Advanced Settings Algorithm 8 Bit Chan Control Item Default Range Function 1 n CCT 0 0 255 2800K 5600...

Page 8: ...White Full White Channel Personality Intensity Linear Standard Channel Personality Advanced Settings Energy Full Eco Channel Personality Advanced Settings Refresh Rate Advanced Settings Algorithm 8 B...

Page 9: ...Advanced Settings Algorithm 8 Bit Chan Control Item Default Range Function 1 n CCT 0 0 255 2800K 5600K 2 n 1 Correction 127 0 255 10 Magenta 10 Green 127 No Correction 3 n 2 Intensity 0 0 255 0 100 16...

Page 10: ...e color value 2 n 1 Y 0 0 255 Y coordinate color value 3 n 2 CCT 0 0 255 2800K 5600K 4 n 3 Correction 127 0 255 10 Magenta 10 Green 127 No Correction 5 n 4 Intensity 0 0 255 0 100 16 Bit Chan Control...

Page 11: ...ct color from the CIE 1931 2 Observer color space To determine the DMX decimal values for a given coordinate simply multiply the coordinate by 255 For example 3200K white light has an x value of 0 425...

Page 12: ...4 channels will be added if 16 bit control is being used CCT channel s then Correction channel s Intensity Available Options Linear Standard Users may select either from a linear dimming curve or squa...

Page 13: ...be removed while using standalone control Use the up and down arrows to select the parameter to change then use the left right arrows to change the parameter Pressing the X button will return to the...

Page 14: ...14 Prism Projection Inc 8228 East 124th Street South Sully IA 50251 1 641 594 3356 info prismprojection com To receive an electronic copy of this user manual please scan the QR code below...

Reviews: