Setting Bar Code Parameters
49
NOTE:
If no values are set for parameters
p2-p10
, the default values will be
used. If you have sent a value from the host, this value is active until
you replace it or the printer is reset.
In this example the following parameters are changed on Line 10:
p1
= style (Code 128)
p2
= height (3/12 inch)
p9
= human readable font (use special font)
The semicolons are “place holders” for the parameters not being changed.
A list of the 10 parameters and their values follows.
p1
Selects the style.
Table 17.
p1
Values
If
p1
=
Style
0
Interleaved 2/5
1
German PTT Interleaved 2 of 5
2
Matrix 2 of 5
3
Industrial 2 of 5
4
Code 3/9
5
EAN-8
6
EAN-13
7
Code 11
8
Reserved
9
Codabar a/t
10
Codabar b/n
11
Codabar c/*
12
Codabar d/e
13
UPC A
14
UPC E