Operating machine
Primo Roasters have 3 or 4 switches depending on model. The switches in order
from left to right: Ignition (IGN), Drum (DRUM), Cooler (COOLER), & Agitator (AGT).
Every Primo Roaster is outfitted with a LCD screen. This LCD screen shows your
current drum temperature, Temp 1 & Temp 2 set points, and your Burners switch (ON/
OFF).
i. Starting Roaster
1. Make sure roaster is properly connected to correct gas source.
2. Make sure roaster is properly plugged in to correct outlet.
3. Make sure the chaff bin is empty and that the under cooler & side panels are
clean of debris.
How to turn roaster on:
ii. Roasting
1. Preheat roaster before first roast for 15-20 minutes or at 400 F.
2. Turn Drum on by pushing in the drum switch on the control panel of the roaster.
3. Next push in the ignition switch next to the drum switch to activate the LCD
screen.
4. Press the ON button located on the LCD screen to ignite the burners.
5. Push temp 1 button on the LCD, use keypad to set desired temperature.
6. Push temp 2 button on the LCD, use keypad to set desired temperature.
7. Let roaster preheat to desired temperature and stay constant for 3 minutes.
8. Fill hopper with raw material.
9. Once filling stops pull funnel slide gate open to allow material to fall into the
drum.
10.Close funnel slide gate.
11.Once the material reaches desired temperature turn on the agitator switch and
the cooler switch.
12.When material is finished open drum door to allow all material to fall into the
cooling tray.
13.Allow machine to reheat prior to next material.
14.Open discharge gate to allow first roast to be transported before the new roast
reaches desired degrees.
15.Close discharge gate when all roasted material is out of cooling tray to prepare it
for the batch currently roasting.
16.Repeat steps for multiple batches.
Summary of Contents for RAVEN XR15
Page 1: ......
Page 5: ...Frontview Scale 1 32 ...
Page 6: ...Leftside view Scale 1 32 ...
Page 7: ...Rearview Scale 1 32 ...
Page 8: ...Rightside view Scale 1 32 ...
Page 9: ...Topview Scale 1 32 ...
Page 10: ...Frontviewwith cyclone Scale 1 32 Roaster to Cyclone Connection Not Pictured Above ...