Operate Elapsed Timer
An Elapsed Timer is a multi-function device that can operate as a digital clock displaying its synchronized time and as a
timer with both count up and count down options. The three-button Timer Control Switch allows a user to start, stop,
pause and reset the timer, and set its start time. When not in a count mode, the timer displays its synchronized time.
• Timer Control Switch: connected to device's RJ11 port. The Timer Control Switch can simultaneously activate two
connected devices for even more accurate time management.
• Manage count events: event is activated, paused, and stopped by end user from Timer Control Switch.
• Set to begin at a time increment an event can be set to begin its count down or count up from a specific time
increment. A count up event starts at the 00:00:00 time increment and a count down event starts at the 99:59:00 time
increment. Either of these can be set to a specific increment through the Timer Switch Control.
Timer Control Switch overview
Count Up and Count Down events are triggered by the use of the three-button Timer Control Switch allowing a user to
control events and allows a user to set to a count event start time.
Timer operation mode (black text)
Set event start time (red text)
Display: Set timer mode (clock, count up, count down)
Exit: Exit from set state
Stop/Start: Manage count event (start, stop, pause)
Increment: Set digit value
Reset: Resets count event
Set/Change: Hold to set start time. Press to change
digit.
An Elapsed Timer has three operating modes that are controlled by the Timer Switch Control.
Page 21