Page 4
LED Indicators
System and Ports
LED
Color
Function
PWR
Green
Indicates that the switch has power.
LNK/ACT
Green
Indicates the link through that port is
successfully established.
Blinks: Indicates that the switch is actively
sending or receiving data over that port.
PoE-in-
Use
Amber
Indicates the port is providing DC in-line
power.
Off: Indicates the connected device is not a
PoE powered device (PD).
PoE Power Usage of PXU-1G44 125-1892 (Unit: Watt)
LED
Color
Function
15
Amber
Off
PoE usage is less than 7W.
Blinks PoE usage is around 8W to 14W.
Lights PoE usage is over 15-watt PoE
power budget.
30
Amber
Blinks PoE usage is around 23W to 29W.
Lights PoE usage is over 30-watt PoE
power budget.
45
Amber
Blinks PoE usage is around 38W to 44W.
Lights PoE usage is over 45-watt PoE
power budget.
60
Amber
Blinks PoE usage is around 53W to 59W.
Lights PoE usage is at the maximum.