Primepower EDR 12 75 Manual Download Page 3

 

g

s

g

 

www.primepower.se

 

 

 

www.primepower.se

 

EDR MANUAL 

 

Mode of operation 

The  Leab  EDR  is  an  electronically  controlled 

relay  for  charging  two  or  more  batteries.  The 
EDR  is  installed  between  the  primary  and  the 
secondary  battery.  The  relay  is  open  until  the 
primary  battery  reaches  the  correct  voltage.  It 
then  closes  and  both  batteries  are  charged  until 
full.  When  consuming  energy  the  battery  voltage 
will  sink.  The  relay  then  opens  and  continued 
consumption  will  only  affect  the  primary  battery 
leaving  the  secondary  battery  next  to  fully  char-
ged.  The  EDR  unit  has  a  built  in  timer  that 
causes  the  yellow  LED  to  light  up  a  few  seconds 
after  the  primary  battery  reaches  correct  vol-
tage  and  goes  out  a  few  seconds  after  charging 
stops. 

Installation 

Install  the  EDR  preferably  vertical  with  the 

cable  connectors  down.  Use  maximum  1  m  long 
cables  to  the  primary  battery.Use  cables  with 
minimum 10 mm

2

 area. 

Electrical connection 

Detach  the  connectors  from  the  positive  po-

les  on  both  batteries.Connect  the  EDR  accor-
ding  to  picture  no  1.  Reconnect  to  the  positive 
poles. 

Test of installation when connected acc. to 

picture no 2 : 

* Turn on lamp connected to secondary battery. 

* Detach connection from positive pole on se-

 

condary battery. The lamp should go off. 

* Start and rev up engine.After a while the lamp 

should light up again together with the yellow 

LED. 

Note!  An  alternator  normally  gives  14(28)V. 

The  EDR  needs  minimum  13,5(27)V  to  work 
also  under  load.  Check  voltage  on  primary 
battery poles. 

* Stop engine and reconnect positive pole again. 

 
 
 
 
 
 
 

 

Technical specifications 

EDR 
Voltage  Normal 

Maximum 

12/75 

   12 
   18 

24/50 

 24 
 30 


Current 

75 

50 

Power cons.  off 

<1,0 

<1,0 

mA 

on 

280 

230 

mA 

Max Capac. 
sec.  battery 

400 

250 

Ah 

Size 

(l*w*h) 

70*75*32  70*75*32  mm 

Weight 

100 

100 

gr 

 

 

---------> 

Cons. 

Battery 

 

charger 

EDR 

Starter 

Battery 

No. 2 

No. 1 

Connections 

30 = In 
87 = Out 
86 = Ground 

85 

87 

86 

30 

charger 

No. 3 

 

 

EDR 

Starter 

Battery 

<-------- 

Cons. 

Battery 

Reviews: