Caution:
• Do not install the PRIME Pipe Freeze Protection Cable when the ambient temperature is colder than the minimum installation
temperature of 32°F/0°C.
• These instructions must be saved and made available to the owner and transferred to future owners.
• If after reading the following instructions, you still have questions regarding installation or operation of this heating cable, contact
PRIME technical support at 888-445-9955.
Selecting the Proper Heating Cable
Use the following two tables to select the proper heating cable.
Table 1
Pipe Heating Cable Length Needed
Pipe Diameter (inches)
Pipe Length
1/2”
3/4”
1”
1.25”
1.5”
6
1 6
1 6
1 6
1 6
1 6
7
1 6
1 6
1 6
1 6
1 6
8
1 6
1 6
1 6
2 6
2 6
9
2 6
2 6
2 6
2 6
2 6
10
2 6
2 6
2 6
2 6
2 6
11
2 6
2 6
2 6
2 6
2 6
12
1 12
1 12
1 12
1 12
1 12
13
1 12
1 12
1 12
1 12
1 12
14
1 12
1 12
1 12
1 12 + 1 6
1 12 + 1 6
15
1 12 + 1 6
1 12 + 1 6
1 12 + 1 6
1 12 + 1 6
1 12 + 1 6
16
1 12 + 1 6
1 12 + 1 6
1 12 + 1 6
1 12 + 1 6
1 12 + 1 6
17
1 12 + 1 6
1 12 + 1 6
1 12 + 1 6
1 12 + 1 6
1 12 + 1 6
18
1 18
1 18
1 18
1 18
1 18
19
1 18
1 18
1 18
1 18
1 18
20
1 18
1 18
1 18
1 18 + 1 6
1 18 + 1 6
21
1 18 + 1 6
1 18 + 1 6
1 18 + 1 6
1 18 + 1 6
1 18 + 1 6
22
1 18 + 1 6
1 18 + 1 6
1 18 + 1 6
1 18 + 1 6
1 18 + 1 6
23
1 18 + 1 6
1 18 + 1 6
1 18 + 1 6
1 18 + 1 6
1 18 + 1 6
24
1 24
1 24
1 24
1 24
1 24
25
1 24
1 24
1 24
1 24
1 24
26
1 24
1 24
1 24
1 18 + 1 12
1 18 + 1 12
27
1 18 + 1 12
1 18 + 1 12
1 18 + 1 12
1 18 + 1 12
1 18 + 1 12
28
1 18 + 1 12
1 18 + 1 12
1 18 + 1 12
1 18 + 1 12
1 18 + 1 12
29
1 18 + 1 12
1 18 + 1 12
1 18 + 1 12
1 18 + 1 12
1 18 + 1 12
30
1 30
1 30
1 30
1 30
1 30
31
1 30
1 30
1 30
1 30
1 30
32
1 30
1 30
1 30
2 18
2 18