22
23
Product Specification
Function Option Guide
Error Messages
Product Type
Model Name
Dimensions
Unit Weight
Maximum Water Supply Pressure
Applicable Water Temperature
Electrolysis Method
Cleaning Method
Plate Materials
Plate Number
Plate Type
Flow Control
Alkalilne Setting
Acidic Setting
Purified Setting
Ionized Water Output Rate
Rated Voltage
Power Consumption
Power Supply Device
Display
Filter Life Indicator
Filter Number
Filter Replacement
Filter Life
Filter Composition
Alkaline Water Ionizer
Prime 501S / Prime 701S / Prime 901S / Prime 1101S / Prime 1301S
33cm X 34.7cm X 15cm
6.5 Kg
50 psi
5~30 degree (41~86 F)
Continuous Electrolysis
Automatic & Manual
Platinum Titanium
Prime 501S (5) / Prime 701S (7) / Prime 901S (9)
Prime 1101S (11) / Prime 1301S (13)
Flat or Mesh(Optional)
Automatic
1-2-3-4
1-2-3
1
Max 3 Liters / 1 min
110V, 220V
Prime 501S (350W) / Prime 701S (450W) / Prime 901S (450W)
Prime 1101S (450W) / Prime 1301S (450W)
SMPS
Full Color LED
FND Number Indicator
Dual Filter (2 Filters)
Cartridge
6 Month (20 Liters / 1 day)
Activated Carbon, Sediment Filter, Fiber Filter, Ceramic Ball
Function Code
Description
Display Shows
F-10
F-20
Volume Adjustment
Voltage Adjustment
0(MUTE)-1-2-3-4-5-6-7(MAX)
Hold Down the “MENU” button
for 5 seconds until the menu option
appears on screan.
To increase volume, press “Alkaline”
to decrease volume press “Acidic”
To save adjustment, press “Menu” button.
Hold down the “Menu+ACIDIC” button for
5 seconds until the menu option appears
on screen.
• Press Alkaline Button until the Alkalline
symbol appears and flashes.
• To increase Voltage, press “Alkaline”
to decrease Voltage, press “Acidic” .
• Same process is used for adjusting the
Acidic level.
• To save adjustment, press “Purified”
button.
Alkaline Water Set Voltage range : 1 ~ 240
Acidic Water Set Voltage range : 1 ~ 240
FILTER 1
FILTER 2
FILTER 1
FILTER 2
Error Code
Description
Solutions
ER-1
ER-2
Low Water Pressure :
Water flow from unit is too low
Leaking Problem :
When the unit not working,
water output from flexible hose
or faucet spout.
1. Increase the input water.
2. Water flow sensor malfunction
: Replace the water flow sensor.
1. Inlet Solenoid valve malfunction (no working)
: Replace the solenoid valve.
2. Water flow sensor malfunction
: Replace the water flow sensor.