TROUBLESHOOTING

T

O PREVENT INJURY

,

 

ALWAYS

DISCONNECT

 

THE

 

AIR

 

SUPPLY

 

HOSE

WHEN ADJUSTING

,

 SERVICING OR

DISASSEMBLING THE TOOL

.

F

IRST

:

 

C

HECK THE 

C

OMPRESSED AIR SUPPLY

Many of problems come from a faulty or inadequate
compressed air supply system. Before attempting to
repair  the  tool,  the  following  points  should  be
checked:
• Check the pressure at the output of the compressor;

adjust to 80-100 psi (5.5-7.0 bar) as required.

• Check the tank pressure of the compressor & adjust

the start/stop limits.

• Check  the  air  delivery  system;  a  3/8"  hose  is

recommended.

• Use fewer tools simultaneously; do not exceed the

capacity  of  the  compressor  or  of  the  delivery
system.

• Drain water from the compressor.

S

ECOND

:

 

C

HECK FOR AIR LEAKS

At rest, this tool should not have any air leaks. Before
attempting to repair the tool and replace parts, check
the following:
• Check  all  seals  in  head,  valve  and  piston

assemblies; replace if necessary.

• Check  the  top  edge  of  main  cylinder  for  burrs  or

dents.

• Clean & lubricate the head and valve assemblies;

re-assemble the head assembly carefully.

• Check the interior of the head for scratches.

A more comprehensive list of tips and
hints at

http://ts.primatech.ca/tips

SCHEMATICS

With your tool Serial Number at hand,
go to our support web site to retrieve
the schematic specific to your tool:

http://ts.primatech.ca/145

For more information, contact technical support:

by phone

1 (800) 363-1962

by email

[email protected]

TOOL WARRANTY AND LIMITATIONS

Primatech  warrants  that  newly  purchased  fastening
tools, parts and accessories will be free from defects in
material  and  workmanship  (excluding  wear  parts)  for
the period shown below, after the date of purchase by
the  original  user  as  evidenced  by  a  valid  purchase
invoice.

ONE-YEAR  LIMITED  WARRANTY  will  apply  to  all
parts, except those subjected to normal wear

WARRANTY STATEMENT

Primatech ‘s sole liability hereunder will be to replace
any  part  or  accessory  which  proves  to  be  defective
within the specific time period. Any replacement part or
accessories provided in accordance with this warranty
will carry a warranty for the remainder of the period of
warranty applicable to the part it replaces. When repair
or replacement of part or tool is required, the complete
tool or part(s) must be returned to Primatech or at such
authorized  warranty  service  point  of  Primatech,
transportation prepaid, with a copy of proof of purchase
evidencing that the part or tool is within the warranty
period. Serial # must be intact and legible for warranty
to apply.

This  warranty  is  void  as  to  any  tool  which  has  been
subjected to misuse, abuse, accidental or intentional
damage,  used  with  fasteners  not  meeting  Primatech
specifications, size or quality, improperly maintained,
repaired  with  other  than  genuine  Primatech
replacement parts, damaged in transit or handling, or
which, in Primatech ‘s sole opinion, has been altered,
modified or repaired in a way that affects or detracts
from the performance of the tool.

PRIMATECH MAKES NO WARRANTY, EXPRESSED
OR  IMPLIED,  RELATING  TO  MERCHANTABILITY,
FITNESS,  OR  OTHERWISE,  EXCEPT  AS  STATED
ABOVE, and Primatech‘s liability AS STATED ABOVE
AND  AS  ASSUMED  ABOVE  is  in  lieu  of  all  other
warranties arising out of, or in connection with, the use
and  performance  of  the  tool,  except  to  the  extent
otherwise provided for by applicable law.

PRIMATECH SHALL IN NO EVENT BE LIABLE FOR
ANY  DIRECT,  INDIRECT,  OR  CONSEQUENTIAL
DAMAGES  WHICH  MAY  ARISE  FROM  LOSS  OF
ANTICIPATED  PROFITS  OR  PRODUCTION,
SPOILAGE OF MATERIALS, INCREASED COST OF
OPERATION,  OR  OTHERWISE.  Any  liability,  if  any,
connected with the use of the tool shall terminate upon
the expiration of the warranty period specified above.

Summary of Contents for P145

Page 1: ...n other than the working area Always carry or manipulate the tool by its handle while the air supply hose is connected Never hit the head cap of the actuator if the base is not sitting perfectly on the working surface Never leave the tool laying down on its side while the air supply hose is connected the tool should always be left on the floor standing on its base Always disconnect the air supply ...

Page 2: ...ssure higher than 110 psi 7 6 bar PREVENTIVE MAINTENANCE This tool requires minimal lubrication Use only detergent free oil such as Primatech P 090 Few drops of oil weekly in the air inlet is sufficient Other types of lubricant may degrade the seals Check periodically to make sure that the head assembly is fully screwed onto the main body A loosen head will damage the tool LOADING THE TOOL This to...

Page 3: ...E REPAIR Most maintenance to the tool can be made with the 5 mm Allen wrench supplied with the tool Disassembly of the tool must be done in a clean environment Some parts can be easily damaged if disassembled with improper tools or by inadequate methods Maintenance should only be performed by trained personnel Use only genuine Primatech replacement parts To prevent injury ALWAYS disconnect the air...

Page 4: ... gate foot assembly guiding channel Insert the valve assembly into the head Inspect the head gasket replace if necessary Place the gasket into the groove on the head flange Some oil or grease will help to keep it in place during assembly Insert the head assembly onto the body making sure that the gasket stays in place Screw in place After reassembly always actuate the tool repeatedly WITHOUT FASTE...

Page 5: ...E YEAR LIMITED WARRANTY will apply to all parts except those subjected to normal wear WARRANTY STATEMENT Primatech s sole liability hereunder will be to replace any part or accessory which proves to be defective within the specific time period Any replacement part or accessories provided in accordance with this warranty will carry a warranty for the remainder of the period of warranty applicable t...

Reviews: