Priman PN-8830 Quick Start Manual Download Page 9

                                                       Model:PN-8830 

 

8.0 Maintenance 
 
8.1 Routine Maintenance 
 
Change Filter Elements (Minimally every 6 months) 
Caution: Perform Element changes only when system is depressurized. 
 

1. Unscrew/detach the filter housing from the filter head and drain off any oil in the 
housing into a suitable container.   
 
2. Remove and discard the used element. Replace the element with a new one of the 
appropriate grade.   
 
3. Screw/reattach the filter housing back onto the filter head. Do not over tighten. 
Housing is sealed with an o-ring, so gently hand-tighten. 
 
4. Repeat this process for both filters. 

 
8.2 Routine Maintenance Schedule 
 
Daily 

1. Check for air and nitrogen leaks. Tighten or re-tape fittings as necessary. 
2. Check that the inlet pressure is within recommended operating range. 
 

Weekly 

Clean unit as necessary. 
 

Every Six Months 

Replace filter elements. 
 

ZHUHAI PRIMAN AUTO MAINTENANCE EQUIPMENT CO.,LTD 
ADD:2# Plant, Minghong industry base Liangang industrial zone. Zhuhai City.   
     Guangdong Province P.R. China. 
Tel:86-756-7799055     Fax:86-756-6210996 
Email:[email protected] 
Web:Http://www.zhpriman.com 

Summary of Contents for PN-8830

Page 1: ...r hose s to tire valve stem s 3 Turn red valve handle to the FILL position 4 Press FILL PURGE once for standard inflation or Push and hold FILL PURGE for 2 seconds for nitrogen conversion 5 When unit...

Page 2: ...Specifications may vary for non standard equipment Contact your service agent for further information 1 3 Safety General The unit has standard process plant components and electrical equipment which...

Page 3: ...ge Hooks 4 Air Supply Caution Compressed air should be supplied to the unit with the air dried to a dew point temperature lower than the expected minimum ambient temperature Typical dew point from a p...

Page 4: ...WARNING To avoid the risk of personal injury especially to the eyes face and skin DO NOT direct the air stream at any person s CAUTION To avoid equipment damage never exceed the maximum inlet pressur...

Page 5: ...Increase final target pressure 3 Power Switch Turns unit on and off 4 FILL PURGE Inflation Deflation start 5 Fill Control Valve 6 Outlets For tire fill hoses 7 Compressed Air Inlet 8 Nitrogen Pressure...

Page 6: ...ting the hoses When topping off a single tire there is no need to wait for pressure equalization 7 Turn the Fill Control Valve handle to the STOP position 8 Immediately disconnect the tire fill hoses...

Page 7: ...ressure Check the supply pressure commences but does not complete ERROR CODES ER1 Unstable pressure faulty hose Replace the hose connector connector ER2 Persistent unstable pressure Replace the hose c...

Page 8: ...ion Error Unit requires calibration contact your local distributor or service agent ER9 Automatic Calibration Check Reset machine by Calibration Error switching off power for 5 seconds The ER9 message...

Page 9: ...to the filter head Do not over tighten Housing is sealed with an o ring so gently hand tighten 4 Repeat this process for both filters 8 2 Routine Maintenance Schedule Daily 1 Check for air and nitroge...