Specifications
Power Ultralinear
38 Watts per channel
Power Triode
21 Watts per channel
Frequency Response
10Hz - 30 kHz +/- 1 dB
THD with AABB
< 0,22% @ 1W; less than 1,2% at rated power
S/N Ratio
89 dB
Input Impedance
100 kOhm
Input Sensitivity
270 mV (for rated power at maximum volume setting)
Maximum Gain
36,5 dB
Power Consumption
250 Watts
Net Weight
63.8 lbs / 29 kg
Shipping Weight
70.5 lbs / 32 kg
Dimensions
15.9" x 15.2" x 8.3" / 405 mm x 385 mm x 210 mm (L x W x H)
Shipping Dimensions
22.7" x 18.4" x 12" / 577 mm x 468 mm x 305 mm (L x W x H)
Inputs
5 pairs Stereo RCA, 1 pair Home Theater Input
Outputs
1 pair Stereo RCA Tape, 4 & 8 Ohm Speaker Taps
Tube Complement
4 x KT-88
2 x 12AX7
2 x 12AU7
Remote control
Heavy Metal System Remote Control
As of July 1, 2006 all PrimaLuna products are manufactured with RoHS compliant parts.
PrimaLuna
®
DiaLogue Two
Troubleshooting
Some tips:
• No output. Power is on, but power LED is off and tubes do not light up.
Mains fuse is out. Replace fuse as per instructions on page 9.
•
No output. Power LED is on and tubes do light up normally.
Plate fuse may be out. Replace fuse as per instructions on page 9.
If the new fuse goes out immediately after replacement, contact us for further assistance.
• Noise coming from one channel.
Noisy tube. First swap the 12AX7 tubes left to right. If noise follows tube swap, than you have
found the problem tube. If noise does not follow, swap the 12AU7 tubes left to right.
• Hum coming from one channel.
Possible bad output tube. Swap the KT-88 tubes in pairs from right to left. If hum follows the swap,
swap the far left and far right tubes. If the hum returns to the original problem channel, you have
found the problem tube. If not, swap the inside KT-88 tubes left to right.
• Noise/distortion coming from both channels.
Tubes may be in need of replacement. Read page 8 for tube basics and replacement options.
• Remote control does not function. Check batteries and if necessary, replace with new.
If you try these possible solutions and problems persist, contact us or your local distributor for further