DISPLAY AND SYMBOLS

The display should be checked every time you turn on the instrument. The meter 

momentarily shows all the symbols that may appear in the display. Regular mo- 

nitoring of all the display symbols prevents a misinterpretation of the instrument 

due to defects in the display.

The symbols on the display have the following meanings:

1. 

Data-chip inserted

2. 

Meter mode in use

3. 

Battery level indicator

4. 

Test results and other messages

5. 

Units of measure

6. 

Parameter being tested

7. 

Temperature indicator

8. 

Time

9. 

Day, Month, Year

10. 

Beeper

Meter’s modalities

The meter has three modalities:

STANDBY

 

It’s  the  default  mode  that  appears  every  time  you  turn 

on the instrument by pressing the ON switch. The strip 

symbol will flash and the display will show the number of 

the data chip, the date and time.

Rear

Front

THE DIGITAL METER

General overview of the meter

1. 

Display

2. 

Switch on button

3. 

‘+’ button

4. 

‘-’ button

5. 

Test strip slot

6. 

PC cable port

7. 

Cover

8. 

Battery space

9. 

Data-chip slot

10. 

Strip ejection button

Summary of Contents for PL300

Page 1: ... DIAGNOSTIC DEVICE PRIMA SELF TESTING KIT TRIGLYCERIDES CHOLESTEROL GLUCOSE ENGLISH PL300 PL311 Made in Italy PRIMA Lab SA Via Antonio Monti 7 6828 Balerna Switzerland info primahometest com primahometest com ONLY FOR THE PRIMA IN 0344 ...

Page 2: ...rent types of stripes In case of any questions please call customer service INDEX What s the Prima 2in1 3in1 system for 3 Contents of the packaging 4 The digital meter 5 Display and symbols 6 Setting up the meter for the first time 7 Inserting the batteries 8 Meter settings SET 9 Requirements to perform a measurement 11 Introduction to test strips and data chips 11 Programming the device 12 How to...

Page 3: ...abetes hypertension hypercholesterolemia and family factors also linked to an unhealthy lifestyle such as smoking alcohol abuse and a diet rich in saturated fats in combination with a lack of physical activity In ad dition stress oral contraceptives and pregnancy can cause elevated cholesterol levels A high concentration of cholesterol is a major risk factor for cardiovascular events The Canadian ...

Page 4: ...dicator 4 Test results and other messages 5 Units of measure 6 Parameter being tested 7 Temperature indicator 8 Time 9 Day Month Year 10 Beeper Meter s modalities The meter has three modalities STANDBY It s the default mode that appears every time you turn on the instrument by pressing the ON switch The strip symbol will flash and the display will show the number of the data chip the date and time...

Page 5: ...2032 in the slot as shown paying at tention to the symbols and ends of the batteries Use only 3V lithium batteries CR 2032 Remember to always change both batteries at the same time as batteries with different capacity may interfere with the functionality of the instrument 3 Close the battery compartment by sliding the cover until you hear a click 4 Turn the instrument to test the operation of the ...

Page 6: ...wer right corner To set the preferred format press and release the power button to access the SET until you see the format blink Press the or to select date formats To select the month day and year press and release the power button until the signal does not blink Press or buttons to set the correct month Press power to confirm and go to the next setting Similarly also set the date and year by pre...

Page 7: ...or tests which require one or two drops of blood An ad CH REQUIREMENTS TO PERFORM A MEASUREMENT Your PRIMA Self Testing device 2in1 or 3in1 Test strips for measuring the desired parameter on chip data Lancing Device Sterile Lancet User s manual Cotton swab or gauze not included Diary where you record the results not included INTRODUCTION TO TEST STRIPS AND DATA CHIPS The basic package of PRIMA Sel...

Page 8: ...g de vice by turning it counterclockwise while holding the base 3 While holding the lancet carrier insert a new sterile lancet into the bottom of lancet carrier Twist the cap of the lancet off 5 Hold the tip firmly in one hand then pull out the sliding barrel with the other hand This will cock the lancing device 2 With two fingers pull out the lan cet carrier and hold it in place 4 Put the tip of ...

Page 9: ...tainer Close the container immediately after removing strip to protect the desiccants and re maining strips otherwise the test strips may become unusable before expiry date Liquids must not enter the test strip container Hold the test strip with thumb and index finger so that the blood sample appli cation area is facing upwards Insert the test strip into the designated strip slot From the printing...

Page 10: ...the proceeding instructions of this manual Perform another measurement us ing a new test strip If the new result also seems to be not plausible consult your doctor When measurement is complete use the ejector key on the back of the meter to remove the used strip Press power button until the instrument powers off Properly dispose of the used lancets and test strip according to your local laws and g...

Page 11: ...tton clean tissue or cloth Mild soap as well as 70 alcohol or isopropanol al cohol are suitable to moisten the cotton cloth to clean plastic surfaces Lift the front cover and gently clean glass surfaces of the optic with a dry gauze or cotton ball Clean plastic cover support of the meter with mois tened and then dry gauze or cloth Do not use any disinfectant sprays or cloth cotton balls which are ...

Page 12: ...dling accident and or negligent care IMPORTANT NOTES Always Operate the instrument within the acceptable temperature range Place the instrument on a level surface or hold it steady in your hand Make sure that all display elements are functioning during the self test Read the test strip inserts Keep the meter and the test strip container clean and tidy To get less variable results fast at least 10 ...

Page 13: ...cets 5 cholesterol strips 5 triglycerides strips 10 glucose strips PL311 Sterile lancets for Lancing device 50 Sterile lancets 100 Sterile lancets PL313 PL314 PRODUCT LIMITATIONS Please read the instructions of use for the test strips and control solutions for detailed information on product data and the respective limits of the test PRIMA Glucose test strips with the blue data chip and PRIMA Gluc...

Page 14: ...25 26 LOGBOOK Write down the results you get with the PRIMA device ...

Reviews: