Prilux flexiLIGHT 146432 Manual Download Page 9

 

LED 24V

CODE

CONS./CUT UNIT

LED COLOR

Nº LEDs/cm

CUT UNIT

DIAMETER

146432

0,36W

Warm white

30

20cm

13mm

149167

0,36W

Cool white

30

20cm

13mm

191876

0,36W

Blue

30

20cm

13mm

191883

0,36W

Green

30

20cm

13mm

191906

0,36W

Red

30

20cm

13mm

191913

0,36W

Yellow

30

20cm

13mm

ACCESSORIES (NOT INCLUDED)

194556

Adapter

150323

Rectifier máx. 60W

364478

Rectifier máx. 96W

149181

Transformer 10,8W

149198

Transformer 28,8W

149204

Transformer 60W

149211

Transformer 120W

24V dc

 

 

IP44

 

 

60º

-20º

 

30m

 

 

 

MAINTENANCE OF THE PRODUCT

ALL PRILUX CHRISTMAS LIGHTING MOTIF,  NEED A 

MAINTENANCE BEFORE BEING USED, IT MEANS TO 

CHECK ALL THE CONNECTIONS (INCLUDED THE END 

CAP) IN ORDER TO BE SURE THAT THE MATERIAL HAS 

THE PERFECT TIGHTNESS.

WARNING

BEFORE STARING THE INSTALLATION OF THIS PRO-

DUCT , PLEASE READ ATTENTIVELY THE INSTRUCTIONS 

AND KEEP THEM IN A SAFE PLACE.

THE INSTALLATION SHOULD BE PERFORMED BY QUA-

LIFIED PERSONNEL.

THE IMPROPER HANDLING OF THE COMPONENTS 

OR THE PRODUCT COULD DAMMAGE THE CORRECT 

FUNCTIONING OF THIS DEVICE THUS CANCELLING 

THE WARRANTY OF THE PRODUCER

THE WARRANTY OF THE PRODUCER IS CANCELLED IF 

THE INSTALLATION IS NOT PERFORMED FOLLOWING 

THE INDICATED IN REBT 2002.

THE APPLICATION ITC BT09-4 OF THE  REBT IS MAN-

DATORY (INSTALLATION OF OVERVOLTAGE PRO-

TECTORS OF IN LINES AND RECEIVERS) FOR INDUS-

TRY INSTALLATIONS AND PUBLIC LIGHTING. THE 

WARRANTY DOES NOT COVER DAMMAGES PRO-

DUCED BY OVERVOLTAGE ON RECEIVERS WITHOUT 

OVERVOLTAGE PROTECTORS.
THE APPLICATION OF ITC BT19 ( INTERIOR OR RECEI-

VING INSTALLATIONS.GENERAL PRESCRIPTIONS) IS 

MANDATORY.
THE APPLICATION OF ITC BT34 (INSTALLATIONS FOR 

SPECIAL PURPOSES. FAIRS AND STANDS) IS MANDA-

TORY.

[GRÁFICOS: Unidades en mm/ GRAPHICS: Units in mm/GRAPHIQUES: Unités en mm/GRÁFICOS: Unidades em mm]

Summary of Contents for flexiLIGHT 146432

Page 1: ...ULADA LA GARANT A DEL FABRI CANTE QUEDA ANULADA LA GARANT A DEL FABRICANTE SI LA INSTALACI N NO SE REALIZA SEG N LO INDICA DO EN EL REBT 2002 ES DE OBLIGADO CUMPLIMIENTO LA APLICACI N DE ITC BT09 4 DE...

Page 2: ...dise o profesional Puede decorar tanto interiores como exteriores de edificios se alar algo que sea preciso alrededores de un sitio determinado realizar alg n tipo de signo o iluminar ventanas portale...

Page 3: ...en superficies de madera con pega mento o con cinta adhesiva de doble cara de acuerdo a su dise o Para realizar figuras rectangulares o cuadradas utilice el clip de fijaci n adecuado y f jelo con cuer...

Page 4: ...un enchufe adaptador con fusible para evitar da os por sobrecarga CONEXI N S lo se puede conectar entre si FLEXILIGHT LED con el mismo voltaje Cuando vaya a realizar las conexiones entre piezas de FLE...

Page 5: ...de los cables met licos del interior del hilo ATENCI N ASEG RESE DE QUE LA POLARIDAD Y EL SENTIDO DE LA CORRIENTE SON LOS CORRECTOS 4 Introduzca el termorretr ctil por uno de los extremos del hilo par...

Page 6: ...junta calentando el termo rretr ctil 9 10 11 Repita este proceso en los extremos de los tramos a sustituir colocando un tap n para rematar los tramos finales del hilo No olvide rellenar los orificos...

Page 7: ...24Vdc Adaptador rectificador Flexilight Flexilight 24Vdc CONEXIONADO FLEXILIGHT LED 24V 1 El FLEXILIGHT LED 24V siempre tie ne que utilizarse con el rectificador 150323 m x 60W 364478 m x 96W Y el ada...

Page 8: ...Tel 925 23 38 12 Fax 925 23 38 80 C Bellvei 11 17 Pol gono Can Salvatella 08210 Barber del Vall s Barcelona Espa a Tel 93 719 23 29 Fax 93 719 25 90 Prilux do Brasil Com rcio de Ilumina o LTDA CNPJ 16...

Page 9: ...ASE READ ATTENTIVELY THE INSTRUCTIONS AND KEEP THEM IN A SAFE PLACE THE INSTALLATION SHOULD BE PERFORMED BY QUA LIFIED PERSONNEL THE IMPROPER HANDLING OF THE COMPONENTS OR THE PRODUCT COULD DAMMAGE TH...

Page 10: ...essional design You can decorate both indoors and outdoors from the buildings highlighting something surroundings from a specified place making a kind of symbol or lighting windows entrances stairs tr...

Page 11: ...fixing clip with ropes in wooden surfaces with glue or double face adhesive tape according to its design To make square or rectangular figures use the appropriate fixing clip and set it with ropes You...

Page 12: ...rload CONNECTION Only can be connect between them those luminous thread with the same voltage When it is going to make connections between pieces from the luminous thread o the luminous thread with th...

Page 13: ...through wire pin inside the holes of the internal wires WARNING MAKE SURE THAT THE POLARITY AND THE POWER DIRECTION ARE CO RRECT 4 Enter a shrink in the wire s side for its subsequent sealing 5 Procee...

Page 14: ...REPAIR OF THE SEGMENT WITH SPLICE FLEXILIGHT 7 8 Seal the seam by heating the shrinkable 9 10 11 Repit this process at the ends of every sections to be replaced 12 Set the new sections to the metalic...

Page 15: ...dc Adapter rectifier Flexilight Flexilight 24Vdc FLEXILIGHT LED 24V CONNECTION 1 FLEXILIGHT LED 24V must be used with the rectifier 150323 m x 60W or 364478 m x 96W And it is also necessary to use the...

Page 16: ...Tel 925 23 38 12 Fax 925 23 38 80 C Bellvei 11 17 Pol gono Can Salvatella 08210 Barber del Vall s Barcelona Espa a Tel 93 719 23 29 Fax 93 719 25 90 Prilux do Brasil Com rcio de Ilumina o LTDA CNPJ 16...

Page 17: ...NSTALLATION DE CE PRODUIT VEUILLEZ LIRE ATTENTIVEMENT LES INS TRUCTIONS ET GARDEZ LES L INSTALLATION DOIT TRE R ALIS E PAR DU PERSON NEL QUALIFI LA MANIPULATION INCORRECTE DES COMPOSANTS OU DU PROPRE...

Page 18: ...fessionnel Vous pouvez d corer l int rieur et l ext rieur des b timents en soulignant quelque chose environs ou un lieu d termin faisant une sorte de symbo le ou d clairage fen tres les entr es les es...

Page 19: ...des dans les surfaces en bois avec de la colle ou du ruban adh sif double face selon son design Pour faire des figures carr es ou rectangulaires utilisez le clip de fixation appropri et r glez le avec...

Page 20: ...le bouchon a t r solu avec la s curit au bord du fil lumineux Ne branchez pas la guirlande au fournisseur de puissance alors qu il est dans son emballage moins que le paquet a un sens d coratif Assur...

Page 21: ...rous des fils m talliques dans l axe du fil ATTENTION ASSUREZ VOUS QUE LA POLARIT ET LA DIRECTION DE LA PUISSANCE SONT CORRECT 4 Entrez un psy par une extr mit du fil pour la fermeture ult rieure 5 Pa...

Page 22: ...ASSEMBLAGE R PARATION DU SEGMENT FLEXILIGHT SPLICE 7 8 Sceller le joint en chauffant le psy 9 10 11 R p tez ce processus sur les extr mit s des sections remplacer 12 Set m ches la structure du moyen...

Page 23: ...Adapteur redresseur Flexilight Flexilight 24Vdc CONNEXION FLEXILIGHT LED 24V 1 FLEXILIGHT LED 24V doivent tre utilis s avec le redresseur 150323 m x 60W ou 364478 m x 96W Et il est galement n cessaire...

Page 24: ...Tel 925 23 38 12 Fax 925 23 38 80 C Bellvei 11 17 Pol gono Can Salvatella 08210 Barber del Vall s Barcelona Espa a Tel 93 719 23 29 Fax 93 719 25 90 Prilux do Brasil Com rcio de Ilumina o LTDA CNPJ 16...

Page 25: ...CEPTORES EM INSTALA ES INDUSTRIAIS E ILUMI NA O P BLICA A GARANTIA N O COBRE DANOS PROVOCADOS POR DESCARGAS EM APARELHOS SEM PROTEC O CONTRA SOBRETENS ES OBRIGAT RIO O CUMPRIMENTO DA NORMA ITC BT19 IN...

Page 26: ...um projeto profissional Voc pode decorar tanto interiores como exteriores dos edif cios destacar alguma coisa arredores ou um lugar determinado fazer esp cies de s m bolo ou ilumina o janelas entrada...

Page 27: ...om cordas em superf cies de madeira com cola ou fita adesiva dupla face de acordo com o seu desenho Para fazer figuras quadradas ou retangulares utilize o clipe de fixa o adequada e configur lo com co...

Page 28: ...ador com fus vel a fim de evitar qualquer dano contra sobrecarga CONEX O S pode ser ligar entre eles aqueles fio luminoso com a mesma tens o Quando ele vai fazer conex es entre pe as do fio luminoso o...

Page 29: ...trous des fils m talliques dans l axe du fil ATTENTION ASSUREZ VOUS QUE LA POLARIT ET LA DIRECTION DE LA PUISSANCE SONT CORRECT 4 Entrez un psy par une extr mit du fil pour la fermeture ult rieure 5 P...

Page 30: ...TAGEM REPARA O DO SEGMENTO FLEXILIGHT COM SPLICE 7 8 Selar a costura por aquecimento do termorretr ctil 9 10 11 Repita este processo as extremida des das sec es 12 Set vagueia a estrutura do funda men...

Page 31: ...Vdc Adaptador rectificador Flexilight Flexilight 24Vdc CONEX O FLEXILIGHT LED 24V 1 El FLEXILIGHT LED 24V sempre voc tem que usar o retificador 150323 m x 60W ou 364478 m x 96W E tamb n necess rio uti...

Page 32: ...Tel 925 23 38 12 Fax 925 23 38 80 C Bellvei 11 17 Pol gono Can Salvatella 08210 Barber del Vall s Barcelona Espa a Tel 93 719 23 29 Fax 93 719 25 90 Prilux do Brasil Com rcio de Ilumina o LTDA CNPJ 16...

Reviews: