Quantum Dynamo ATS RevB/Jun04
www.pridemobility.com
21
Power Module
Typically, the power module is mounted to the power base. The power module provides a power interface for the joystick
module. It routes the battery power to the motors and other powered accessories such as lights and power seats.
ACTUATOR LIGHTING MODULE (NOT SHOWN)
The actuator lighting module is also located on the power base. The actuator lighting module provides a control and power
interface between the power module, the lights, and/or the power seat actuator.
SLEEP MODE
Your Remote Plus controller has a sleep mode feature. Sleep mode is a built-in circuit that automatically shuts off the main
power if the joystick is not moved in any direction for approximately five minutes. The battery condition metre lights on the
keypad indicate sleep mode by blinking once every five seconds. To restore power and continue, push the on/off key twice.
THERMAL ROLLBACK
The Remote Plus is equipped with a thermal rollback circuit. This circuit monitors the temperature of the motors, power
module, and remote. In the event that any of them become excessively hot (above 50°C/122°F), motor voltage is reduced. For
every degree above 50°C/122°F, the voltage is reduced by 5 volts. This reduces your power chair’s speed and allows the
electrical components to cool down. When the temperature returns to a safe level, your power chair resumes its normal
speed.
TROUBLE CODES
In addition to indicating the current state of battery charge, the battery condition metre can also indicate possible problems
with your power chair. The battery condition metre has ten lights. The lights provide information by the number of lights that
are flashing. If any of the metre lights are flashing rapidly, the controller may be indicating a fault. For instance, if the first light
is flashing rapidly, the battery voltage is nearly depleted. The following is a list of the possible errors signified by the rapidly
flashing metre. When you get a trouble code, contact your authorised Pride Dealer.
OPERATION
FLASHING
DIAGNOSIS
SOLUTION
LIGHTS
10
High Battery Voltage
Check batteries.
9
Solenoid Brake Fault
Check motor/brake wiring.
8Possible Controller Fault
See authorised Pride Dealer.
7
Possible Joystick Fault
See authorised Pride Dealer.
6
Inhibit Active Unplug charger.
Check connections.
5
Right Motor Wiring Fault
Check right motor wiring.
4
Right Motor Disconnected
Check right motor wiring.
3
Left Motor Wiring Fault
Check left motor wiring.
2
Left Motor Disconnected
Check left motor wiring.
1
Low Battery Voltage
Check batteries/battery wiring.