IUC-7X-TXX
Standard Metal Enclosure
Shown here for
4-20mA Output
Options:
A - 24 VDC Prime Power
B - 240 VAC Prime Power (not CSA approved)
T - 200 mA Two Wire Supply (24 VDC unreg.)
C - Conduit Cover for Metal Enclosure
(see above)
N - NEMA 4X enclosure (see above)
Conduit Cover Option
for Metal Enclosure
Model Designation:
Example: A Thermocouple
Transmitter for type 'K' for
0-500F and 4-20 mA Output
is : IUC-72-TK2
IUC-7X-TXX
Range
J
K
E
T
R
S
0 to 300F
TJ1
TE1
TT1
-18 to 150C
0 to 400F
TJ2
TK1
TE2
TT2
-18 to 204C
0 to 500F
TJ3
TK2
TE3
TT3
-18 to 260C
0 to 750F
TJ4
TK3
TE4
TR1
TS1
-18 to 400C
0 to 1000F
TJ5
TK4
TR2
TS2
-18 to 538C
0 to 1500F
TK5
TR3
TS3
-18 to 816C
0 to 2000F
TK6
TR4
TS4
-18 to 1093C
0 to 3200F
TR5
TS5
-18 to 1760C
-350 to 1100F
TJ6
TK7
TE5
-200 to 600C
1: 1-5 mA (4000 Ohm Drive)
2: 4-20 mA (1000 Ohm Drive)
3: 0-1 mA (20000 Ohm Drive)
4: 10-50 mA (250 Ohm Drive)
5: 1-5 VDC (Zout=250 Ohm)
6: 0-10 VDC (Zout=500 Ohm)
7: Special Output
Output
If no options specified, unit is 117 VAC Power in metal enclosure
Manufactured By:
www.pribusin.com
CANADA:
Pribusin Inc.
101 Freshway Dr. Unit 57
Concord, Ontario, L4K 1R9
Ph: (905) 660-5336
Fx: (905) 660-4068
USA:
www.pribusin.com
USA:
Pribusin Inc.
743 Marquette Ave.
Muskegon, MI 49442
Ph: (231) 788-2900
Fx: (231) 788-2929
Rev.A Subject to change without notice