background image

Enclosures & Dimensions:

Connection:

Page A20

IUC-7X-TXX

Standard Metal Enclosure

Shown here for
4-20mA Output

Options:

A - 24 VDC Prime Power
B - 240 VAC Prime Power (not CSA approved)
T - 200 mA Two Wire Supply (24 VDC unreg.)
C - Conduit Cover for Metal Enclosure

(see above)

N - NEMA 4X enclosure (see above)

Conduit Cover Option
for Metal Enclosure

Model Designation:

Example: A Thermocouple

Transmitter for type 'K' for
0-500F and 4-20 mA Output
is : IUC-72-TK2

IUC-7X-TXX

Range

J

K

E

T

R

S

0 to 300F

TJ1

TE1

TT1

-18 to 150C

0 to 400F

TJ2

TK1

TE2

TT2

-18 to 204C

0 to 500F

TJ3

TK2

TE3

TT3

-18 to 260C

0 to 750F

TJ4

TK3

TE4

TR1

TS1

-18 to 400C

0 to 1000F

TJ5

TK4

TR2

TS2

-18 to 538C

0 to 1500F

TK5

TR3

TS3

-18 to 816C

0 to 2000F

TK6

TR4

TS4

-18 to 1093C

0 to 3200F

TR5

TS5

-18 to 1760C

-350 to 1100F

TJ6

TK7

TE5

-200 to 600C

1: 1-5 mA (4000 Ohm Drive)
2: 4-20 mA (1000 Ohm Drive)
3: 0-1 mA (20000 Ohm Drive)
4: 10-50 mA (250 Ohm Drive)
5: 1-5 VDC (Zout=250 Ohm)
6: 0-10 VDC (Zout=500 Ohm)
7: Special Output

Output

If no options specified, unit is 117 VAC Power in metal enclosure

Manufactured By:

www.pribusin.com

[email protected]

CANADA:

Pribusin Inc.
101 Freshway Dr. Unit 57
Concord, Ontario, L4K 1R9
Ph: (905) 660-5336
Fx: (905) 660-4068

USA:

www.pribusin.com

[email protected]

USA:

Pribusin Inc.
743 Marquette Ave.
Muskegon, MI 49442
Ph: (231) 788-2900
Fx: (231) 788-2929

Rev.A Subject to change without notice