background image

7

EN

Prexiso P40A

Safety Instructions

The person responsible for the instrument 

must ensure that all users understand 

these directions and adhere to them.

Symbols used

The symbols used have the following 

meanings:

WARNING 

Indicates a potentially hazardous situation 

or an unintended use which, if not avoided, 

will result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation 

or an unintended use which, if not avoided, 

may result in minor injury and/or 

appreciable material, financial and 

environmental damage.

        Important paragraphs which must be

        adhered to in practice as they enable

        the product to be used in a technically 

correct and efficient manner.

Permitted use

 

•  Measuring distances

Prohibited use

•  Using the product without instruction

•  Using outside the stated limits

•  Deactivation of safety systems and 

removal of explanatory and hazard 

labels

•  Opening of the equipment by using tools 

(screwdrivers, etc.)

•  Carrying out modification or conversion 

of the product

•  Use of accessories from other 

manufacturers without express approval

•  Deliberate dazzling of third parties; also 

in the dark

•  Inadequate safeguards at the surveying 

site (e.g. when measuring on roads, 

construction sites, etc.)

•  Deliberate or irresponsible behaviour on 

scaffolding, when using ladders, when 

measuring near machines which are 

running or near parts of machines or 

installations which are unprotected

•  Aiming directly in the sun

Hazards in use

WARNING

Watch out for erroneous measurements if 

the instrument is defective or if it has been 

dropped or has been misused or modified. 

Carry out periodic test measurements.

Particularly after the instrument has been 

subject to abnormal use, and before, 

during and after important measurements.

CAUTION

Never attempt to repair the product 

yourself. In case of damage, contact a 

local dealer.

WARNING

Changes or modifications not expressly 

approved could void the user’s authority 

to operate the equipment.

Limits of use

 

     Refer to section "Technical data".

     The device is designed for use in 

areas permanently habitable by humans. 

Do not use the product in explosion 

hazardous areas or in aggressive 

environments.

i

Summary of Contents for P40A

Page 1: ...IMPORTANT Read before using P40A PENLASER DISTANCE MEASURE WITH CLIP www prexiso eu com 2 WARRANTY LIMITED YEARS 135FT 40M FUNC ...

Page 2: ...rmance of this laser device in any way This may result in a dangerous exposure to laser radiation Do not operate the tool outdoors Do not attempt to repair or disassemble the laser measuring tool If unqualified persons attempt to repair this product serious injury may occur Any repair required on this laser product should be performed only by qualified service personnel Do not stare into the laser...

Page 3: ...e first time The person responsible for the product must ensure that all users understand these directions and adhere to them Display Insert batteries Prexiso P40A 2 EN i Change batteries when battery symbol is empty FUNC Display On Off Measure Units Area Volume Addition Subtraction Unit Battery Measuring Reference Area Volume ftim ftim ...

Page 4: ...ching ON OFF Measurement Reference If no key is pressed for 120 sec the device switches off automatically FUNC 3 sec 1 2 Press button 3 sec to measurement reference mode Press button to UNIT setting mode 3 4 Unit setting FUNC FUNC 4 The measurement and the system recovery to initial setting 3 sec 2 Press button to change the reference to Measurement Reference setting mode FUNC 3 Press button to ch...

Page 5: ...2x 4 EN Measuring Functions 1 2 Stops continuous measuring 3 Continuous measuring The last value measured is displayed Aim active laser at target 49 08 7 16 Area 1x 1 2 Aim laser at first target point 3 4 Aim laser at second target point 5 i The result is shown in the main line and the measured distance above FUNC 29 99 ft2 FUNC ...

Page 6: ...tial state Prexiso P40A 5 EN 4 The result is shown in the main line and the measured distance above 1 Press button to Addition Sub traction mode 3 Then measure the second data Addition subtraction Reset 2 Measure the first data 3X 4X 10 00 109 99 7 16 10 00 89 99 7 16 10 00 or 299 99 ft3 FUNC 1 5 sec FUNC FUNC 1 99 99 7 16 99 99 7 16 ...

Page 7: ...ropriately in accordance with the national regulations in force in your country Adhere to the national and country specific regulations Product specific treatment and waste management can be downloaded from our homepage General Maximum measuring range Measuring accuracy Measuring units Laser class Laser type Autom power switch off Autom laser off Battery durability 2 x AAA Dimension LxWxH Weight w...

Page 8: ...ion of the product Use of accessories from other manufacturers without express approval Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site e g when measuring on roads construction sites etc Deliberate or irresponsible behaviour on scaffolding when using ladders when measuring near machines which are running or near parts of machines or installations w...

Page 9: ...ul interference to radio communications However there is no guarantee that inter ference will not occur in a particular instal lation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the...

Page 10: ...to the guidelines put forth in the instruction manual 3 Any products or parts used for rental purposes damage resulting from shipping claims must be filed with freighter accident abuse act of God misuse or neglect Prexiso will replace or repair the defective unit at its option subject to verification of the defect Any implied warranties arising from the sale of a Prexiso product including but not ...

Reviews: