Other Features
5-32
SLIDE-OUT TROUBLESHOOTING
Error condition or missing operation
condition
When an error condition or a missing operation
condition is present on a slide-out, the green
indicator light on its respective handheld control
starts blinking upon releasing of the IN/OUT
rocker switch.
Turning the ignition OFF and ON again, will stop
the blinking and reset the fault. If the error
condition or a missing operation condition is still
present, the blinking will start again the next time
that the slide-out is operated. So, to get a fault
diagnostic, use the Driver Information Display
(DID) right after operating the slide-out without
cycling the ignition switch.
Fault Diagnostics
To get more specific information about the error
condition or the missing operation condition,
request a diagnostic from the slide-out CECM
using the Driver Information Display (DID).
Check if there are active errors in the slide-out
electrical system. With the
Diagnostics
menu,
highlight
Fault Diagnostics
and then highlight
Electrical System
to request a diagnostic of the
electrical system from the MCM. Press the enter
key.
If applicable, the DID shows the device ID, the
fault messages or fault codes recorded. When
more than one fault is recorded, an arrow
pointing down appears on the right of the
display. Use the down arrow to see all the fault
messages.
Once the problem corrected, the DID still shows
the fault as being active. You have to leave the
Fault Diagnostics
menu, wait approximately 20
to 30 seconds and then return to
Fault
Diagnostics
to request a new diagnostic of the
Electrical System
from the MCM. The DID
should display the fault as being inactive.
TROUBLESHOOTING – OPERATING CONDITIONS, CONTROL & MECHANICAL COMPONENTS
PROBLEM
CAUSE
CORRECTIVE ACTION
The slide-out
functions
normally but
the handheld
control green
indicator light
blinks
A. Something is defective and may eventually
create an issue if not repaired. The problem
may be:
B. Faulty limit sensor causing the slide-out to
stop in overcurrent;
C. CAN network problem causing the
transmission inhibit safety to be non-
operational;
D. Vacuum pressure transducer disconnected or
damaged (vacuum is applied for a fixed time
of 7 seconds);
E. Seal inflating valve solenoid open circuit (the
seal is not re-inflated and water can
penetrate in the vehicle);
F. Security pin valve solenoid open circuit (the
security pin is not extended while vehicle is
riding).
Using the Driver Information Display
(DID), check if there are active errors in
the vehicle electrical system. With the
Diagnostics
menu, highlight
Fault
Diagnostics
and then highlight
Electrical
System
to request a diagnostic of the
electrical system from the MCM.
Summary of Contents for X3-45 VIP 2015
Page 1: ...COACH MANUFACTURER OWNER S MANUAL X3 45 VIP PA1610 Rev 1 February 2015...
Page 6: ......
Page 10: ......
Page 28: ......
Page 134: ......
Page 155: ...Technical Information 9 3 LE MIRAGE XLII OVERALL DIMENSIONS...
Page 156: ...Technical Information 9 4 LE MIRAGE XLII OVERALL DIMENSIONS...
Page 166: ......
Page 170: ......
Page 176: ......