Starting and Stopping Procedures
PA1627 X3-45 Operator’s Manual
6-6
ENGINE BLOCK HEATER
The vehicle may be equipped with an engine
immersion-type electric block heater to assist
cold weather starting. Using an extension cord,
connect to a 110 - 120 VAC outlet.
BLOCK HEATER 120 VOLT CONNECTOR
CAUTION
Connect only to a 110-120 VAC power source.
Use only grounded (three prongs) extension
cords with a minimum rated capacity of 15
amps. Disconnect the extension cord before
starting. Before driving, make sure the
extension cord is disconnected and the engine
compartment door is closed.
ENGINE WARM-UP
After starting the engine, keep the parking brake
applied and let the engine run at normal idle for
two minutes to allow lubricating oil to reach the
turbocharger. Increase engine speed to fast
idle, using the FAST IDLE switch located on the
dashboard for five minutes, without loading the
engine. Monitor the gauges and indicator lights
to make sure all conditions are normal. If an
abnormal condition is observed, stop the engine
immediately and have the condition corrected.
DANGER
Never let the engine run in an enclosed, non-
ventilated area. Engine exhaust fumes contain
dangerous gases which can be fatal if inhaled.
Before warming up the engine, open the
door(s) or move the vehicle outside.
NOTE
The engine will reach normal operating
temperature shortly after driving. Avoid driving
at full throttle until engine coolant temperature
reaches 140°F (60°C).
ALLISON TRANSMISSION WARM-UP
When the transmission temperature falls below
-20°F (-29°C), the CHECK TRANS telltale light
illuminates after the engine is started, and a
reminder tone will sound. In this case, the
transmission will be locked in neutral (N) until
the transmission temperature rises above -20°F
(-29°C) and the CHECK TRANS telltale light
goes out. The transmission will only operate in
first or reverse gears until it reaches normal
operating temperature.
STARTING THE VEHICLE AFTER A
FIRE ALARM
The vehicle may be started after a fire alarm
without resetting the system. Refer to section 7
SAFETY FEATURES AND EQUIPMENT under
“Fire suppression system (AFSS)” for the
complete procedure.
Summary of Contents for X3-45 2017
Page 1: ...OPERATOR S MANUAL X3 45 COACH...
Page 2: ......
Page 3: ...COACH MANUFACTURER OPERATOR S MANUAL X3 45 COACH Model Year 2018 PA1627 September 2017...
Page 8: ......
Page 12: ......
Page 28: ...Coach Exterior PA1627 X3 45 Operator s Manual 2 16...
Page 42: ...Coach Interior PA1627 X3 45 Operator s Manual 3 14...
Page 100: ...Controls and Instruments PA1627 X3 45 Operator s Manual 4 58...
Page 186: ...Care and Maintenance PA1627 X3 45 Operator s Manual 8 22...
Page 200: ...Technical Information PA1627 X3 45 Operator s Manual 9 14...
Page 202: ......