3
Technical Data
Power Requirements
ENGLISH
From 0 A up to 10 A
From 10 A up to 13 A
From 13 A up to 15 A
From 15 A up to 20 A
18 AWG(*)
16 AWG
14 AWG
8 AWG
16 AWG
14 AWG
12 AWG
6 AWG
3 (one grounded)
from 6 to 49 feet | Higher than 49 feet
Ampere
Capacity
Conductors
Extension Gauge
* Using is allowed only if the extension cable have an overcurrent protection device.
AWG = American Wire Gauge. Reference: NMX - J - 195 - ANCE
When using power tools outdoors use a grounded extension cable
labeled “Outdoors Use”. These extension cables are specially manufactured for outdoors use and
reduce the risk of electric shock.
Before using the power cable or any additional flexible cable verify they are not damaged or mishandled. If the cable gets
damaged while being used, disconnect immediately the cable from the power outlet. DO NOT touch the power cable
before disconnecting from the power source. Do not use the tool if the power cable is damaged or mishandled.
Double insulation and reinforced insulation tools are built with
a polarized plug (one prong is wider than the other). This plug fits any polarized
power outlet and can only be connected one way. If the plug does not fit in the
power inlet turn it around. If it still is not fitting contact a qualified electrician or
install a polarized power outlet. By no means modify the plug in any manner.
Both types of insulation eliminate the need of a power cable with three parts with
a ground connection or a grounded power system.
When using an extension cable make sure the gauge is enough for the power your product needs.
A lower gauge cable will cause power drop in the line resulting of power loss and motor overheating.
The following table shows the right size to be used depending on cable’s length and the ampere capability shown in
the nameplate. If you have any doubts use the next higher gauge. The lower the gauge, the heavier the cable will be.
If having any doubt pleas use the next higher caliber.
WARNING
WARNING
WARNING
DES-300P2
25043
Class II
60 Hz
Electric String Trimmer
9”
2,5 A
0.4 Hp
Code
Description
Voltage
Frequency
Current
Power
11 000 RPM
Speed
0.06”
IP20
Cutting Line Diameter
IP Grade
20 minutes’ work per 10 idle. Daily maximum, 1 hour 30 minutes
Work Cycle
Cutting Capacity
Insulation
Tool construction class is: Double Insulation
Thermal insulation on motor winding: Class H
127 V
WARNING
WARNING
Avoid the risk of electric shock or severe injury. When the power cable gets damaged
it should only be replaced by the manufacturer or at a Authorized Service Center.
The build quality of the electric insulation is altered if spills or liquid gets into the tool while in use.
Do not expose to rain, liquids and/or dampness.
Before gaining access to the terminals all power sources should be disconnected.