WARNINGS

Do not connect power supply until fan is completely 

installed. Make sure electrical service to the fan is 

locked in “off” position.

1. Remove unit from packaging and inspect within 15 

days after receipt.  If damaged, report damage to 

carrier.  Do NOT operate this unit with visible 

damage to the blower or impeller assembly

2.  All products with A/C motors installed are 

suitable for use with solid state speed control.  

3. This unit has rotating parts and safety 

precautions should be exercised during 

installation, operation and maintenance.

4. CAUTION: “For General Ventilation Use Only. Do 

Not Use To Exhaust Hazardous Or Explosive 

Materials and Vapors.”

5. 

WARNING!

 To reduce the risk of fire, electric 

shock, or injury to persons- observe the following:

a.   Use this unit only in the manner intended by the 

manufacturer. If you have questions, contact the 

manufacturer.

b. Before servicing or cleaning, switch power off at 

the service panel and lock service panel to prevent 

fan from being switched on accidentally.

c.   Installation work and electrical wiring must be 

done by qualified person(s) in accordance with all 

applicable codes and standards, including fire-

rated construction.

d. Sufficient air flow is needed for proper combustion 

and exhausting of gases through the flue 

(chimney) of fuel burning equipment to prevent 

backdrafting. Follow the heating equipment 

manufacturer’s guidelines and safety standards 

such as those published by the National Fire 

Protection Association (NFPA), the American 

Society of Heating, Refrigeration, and Air 

Conditioning Engineers (ASHRAE) and the local 

code authorities.

e.   When cutting or drilling into a wall or ceiling, do 

not damage electrical wires or other hidden 

utilities.

f.   Ducted fans must always be vented to the 

outdoors.

g. Install fan at least five feet above the floor.
h.  NEVER place a switch where it can be reached 

from a tub or shower.

6. 

WARNING!

 Check voltage at the fan to see if it 

corresponds to the motor nameplate.

7. Guards must be installed when this fan is within 

reach of personnel or within seven (7) feet of 

working level or when deemed advisable for safety.

Fan installation

Step 1

When selecting the fan mounting location, the following criteria should be considered: a) type of 
application; b) proximity to fresh air intakes; c) sound created by fan operation.

 

Select the location on the exterior wall where the fan is to be mounted. Make a hole through the 
wall that is 1/2” larger than the diameter of the fan duct connection collar. A short piece of rigid 
duct (not included) approximately 2” longer than the wall thickness is recommended for use as an 
extension through the wall.

Step 2

Remove the four screws securing the white fan discharge cover and remove the cover. Place the 
fan against the wall, as centered as possible on the wall opening, then mark the location of the 
four backplate mounting holes and the electrical knockout. Drill a hole for the electrical service 
that is 1/8” larger than the size of conduit to be used. A 1” diameter electrical service opening is 
provided on the fan backplate (see dimensional drawing on Page 1). When mounting the fan on a 
masonry wall, drill 7/32” holes for the four anchors and mounting screws (provided). Tap the 
anchors flush into the holes. When mounting the fan on a wood surface, wood screws should be 
used.

  If the fan is to be mounted on a wall surface which is Lapped Siding, a mounting frame 

made from 1x1 board may be necessary for a flush fit (see I-2).

Step 3

Before mounting the fan, bring the electrical supply through the wall. Attach the extension collar 
to the fan duct connection collar. The connection should be as air tight as possible to prevent 
leakage from the wall cavity. Apply a generous amount of polyurethane caulk to the exterior side of 
the fan housing backplate (except the bottom so that water that leaked in can drain back out). 
This will ensure an airtight/waterproof connection between the fan and the wall surface. If a 
mounting frame is used in conjunction with lapped siding, be certain to apply a generous amount 
of caulk between the frame and the wall as well as the fan backplate and the frame. Mount the fan 
to the wall.

  Be certain to make an airtight seal around all interior wall penetrations before 

attaching duct work.

E

G

P

I

Extension Collar 
through wall

Masonry Wall

Optional Standard Fange

Discharge 
Cover 
Mounting 
Screws

Figure 1

Extension Collar 

Lapped Siding 

Wall

Mounting 
Frame

Figure 2