Installation Manual
Prestige-America
25 Riverside Dr. Suite 4
Pine Brook, NJ 07058800.358.8886
RB Model
Exterior Remote Blower
Page 1: ...Installation Manual Prestige America 25 Riverside Dr Suite 4 Pine Brook NJ 07058 800 358 8886 RB Model Exterior Remote Blower ...
Page 2: ...B C D E F G H I RB700 10 10 17 7 8 21 1 4 10 5 7 8 8 1 8 8 1 16 9 1 8 2 3 4 RB1000 10 10 17 7 8 21 1 4 10 5 7 8 8 1 8 8 1 16 9 1 8 2 3 4 RB1200 10 10 17 7 8 21 1 4 10 5 7 8 8 1 8 8 1 16 9 1 8 2 3 4 Dimensional information is in inches ...
Page 3: ... installation Step 1 When selecting the fan mounting location the following criteria should be considered a type of application b proximity to fresh air intakes c sound created by fan operation Select the location on the exterior wall where the fan is to be mounted Make a hole through the wall that is 1 2 larger than the diameter of the fan duct connection collar A short piece of rigid duct not in...
Page 4: ...lling the romex cable through the conduit hole as shown below locations are indicated below and are labeled L for line voltage black wire N for neutral white wire and GND for ground green wire Firmly secure each incoming wire to the proper driver CAUTION maximum terminal block screw torque is 7lb in 0 79 Nm Step 3 Secure the power cable by tightening the romex clamp and replace the fan terminal bo...