background image

14

FIGURE 5: Front Crossover Panel

15

Technical Specifications

50 to 225 Watts per channel

135 Watts RMS
400 Watts peak

114 dB (135 Watts RMS /1m)
119 dB (400 Watts peak /1m)

93dB (2.83 Volts @ 1m)

8 Ohm

29Hz - 22kHz, -6dB

90 degree conical

Less than 1.20% at 135 Watts RMS (50Hz - 20kHz)

Dual Concentric“
250mm (10 ) utilising paper pulp cone with
twin roll impregnated fabric surround

52mm (2 ) round wire voice coil

51mm (2 ) round wire voice coil

Bi-wired, hard-wired passive, low loss. Time compensated.
2nd order compensated LF. 2nd order compensated HF

1.1kHz

+/- 3dB over 1.1kHz to 22kHz shelving
+2dB to -6dB per octave over 5kHz to 22kHz slope

Distributed port

105 litres (3.7 cu. ft.)

1100mm (43

1

/

2

) x 406mm (16 ) x 338mm (13

1

/

2

) (H x W x D)

37 kilograms (81.6

 

lbs)

High density 18mm (

3

/

4

) Birch Ply baffle and rear panel

Top and sides 18mm (

3

/

4

) particle board.

Internally crossbraced and heavily damped.

1300mm (51 ) x 550mm (21

1

/

2

) x 447mm (17

1

/

2

) (H x W x D)

43.5 kilograms (95.9

 

lbs)

RECOMMENDED AMPLIFIER POWER

POWER RATING

MAXIMUM SPL

SENSITIVITY

NOMINAL IMPEDANCE

FREQUENCY RESPONSE

DISPERSION

TOTAL HARMONIC DISTORTION

DRIVE  UNIT

DRIVER TYPE

LOW FREQUENCY

HIGH FREQUENCY

CROSSOVER

CROSSOVER TYPE

CROSSOVER FREQUENCY

ADJUSTMENTS

CABINET

ENCLOSURE TYPE

VOLUME

DIMENSIONS

WEIGHT

CONSTRUCTION

PACKAGE DETAIL

DIMENSIONS

WEIGHT

PERFORMANCE

K

ensington

K

ensington

Summary of Contents for Kensington SE

Page 1: ...n...

Page 2: ...ons Unfasten the bottom of the carton Fold the end leaves out of the way and remove the packing tray to reveal the plinth and bottom of the loudspeaker cabinet Locate and remove from the carton the ac...

Page 3: ...om the power amplifier to each loudspeaker and dividing the electrical signals into high current slow signals and light current fast signals Of course the loudspeaker must be fitted with two pairs of...

Page 4: ...adjusted to reduce or slightly increase the extreme high frequency content if necessary Remember the changes that can be made by moving either control from one position to another are subtle They may...

Page 5: ...component coupling and are placed well away from the driver magnetic field Top quality silver plated Van den Hul wiring is used throughout High current switch blocks with gold plated screw terminals...

Page 6: ...d by faults elsewhere in your system Tannoy Ltd or its authorised Distributor or Service Agent will make the determination of the cause of failure based on physical inspection of the failed parts If y...

Page 7: ...LINK WIRES REMOVED TO GROUND OR EARTH CONNECTION ON AMPLIFIER OPTIONAL HF HF LF LF FIGURE 4 Bi Amping Mode and Earth Ground Lead Connection R L R L HIGH FREQUENCY POWER AMPLIFIER LOW FREQUENCY POWER A...

Page 8: ...shelving 2dB to 6dB per octave over 5kHz to 22kHz slope Distributed port 105 litres 3 7 cu ft 1100mm 431 2 x 406mm 16 x 338mm 131 2 H x W x D 37 kilograms 81 6lbs High density 18mm 3 4 Birch Ply baff...

Page 9: ......

Reviews: